RAM ADDRESS LISTING

The following table describes each address in numerical order. This information is current as of the
revision date of this manual, however, the

handler fi

rmware changes regularly. Please refer to the

Change Over Kit Supplemental Chapter of this manual for addresses/features specific to your system as
shipped from the Exatron factory. Exatron offers free firmware updates upon request, for the life of the
equipment.

TABLE

1

H

ANDLER

RAM

A

DRS

D

ESCRIPTION

ROM

RAM

O

PTIONS

C

OMMENTS

0090

Handler Type

00

00 = Model 3000B with Octoloader
11 = Model 3000A (old model) Black Main Plate
2B = Model 2000B
31 = Model 3010 Hot Rail

0091

# Motors

05

Hex

Decode

Sets the number of motors inherent in the handler:
01 = Output Shuttle Motor
02 = Plunge to Board (Z Motor) C/O Kits
04 = Octoloader Motor
08 = Label Apply Motor. For example:
05 = Octoloader Motor/Shuttle Motor (No Z
Motor) as in DIP Changeover Kits
07 = Octoloader Motor/Z Motor/Shuttle
Motor as in Plunge to Board Change Kits

0092

Full Tube 1000s

30

30 to 39

Sets the 1000s digit for number of devices constituting a
full tube, in ASCII digits.

0093

Full Tube 100s

30

30 to 39

Set the 100s digit for number of devices constituting a
full tube, in ASCII digits.

0094

Full Tube 10s

35

30 to 39

Set the 10s digit for number of devices constituting a full
tube, in ASCII digits.

0095

Full Tube 1s

30

30 to 39

Set the 1s digit for number of devices constituting a full
tube, in ASCII digits.

0096

Test Sol Delay

10

00 to FF

This delay allows “settling” time for the DUT, eliminating
any bouncing motion in the test site before the test
contacts are turned on. Counts down in HEX in 10
millisecond steps. A

PPLIES TO

DIP

AND OTHER

NON

-

PLUNGE

STYLE KITS

.

0097

Start Test Delay

01

00 to FF

Time delay for the test contacts to close before the
handler sends a start test signal to the tester. Allows
the test contacts to fully close before issuing a start
pulse. Counts down in HEX in 1 millisecond steps.

0098

Start Pulse Width

14

00 to FF

Adjusts the start test pulse width. This is allowed to
provide flexibility in interfacing between the handler and
tester/programmers. Counts down in HEX in 1
millisecond steps.

0099

FF