Ram address listing, Ram address listing -6, Exatron 3000b – Extron electronic 3000B User Manual
Page 72

Exatron 3000B
www.exatron.com
4-6
Chapter 4 Handler Setup
RAM ADDRESS LISTING
The following table describes each address in numerical order. This information is current as of the
revision date of this manual, however, the
handler fi
rmware changes regularly. Please refer to the
Change Over Kit Supplemental Chapter of this manual for addresses/features specific to your system as
shipped from the Exatron factory. Exatron offers free firmware updates upon request, for the life of the
equipment.
TABLE
1
H
ANDLER
RAM
A
DRS
D
ESCRIPTION
ROM
RAM
O
PTIONS
C
OMMENTS
0090
Handler Type
00
00 = Model 3000B with Octoloader
11 = Model 3000A (old model) Black Main Plate
2B = Model 2000B
31 = Model 3010 Hot Rail
0091
# Motors
05
Hex
Decode
Sets the number of motors inherent in the handler:
01 = Output Shuttle Motor
02 = Plunge to Board (Z Motor) C/O Kits
04 = Octoloader Motor
08 = Label Apply Motor. For example:
05 = Octoloader Motor/Shuttle Motor (No Z
Motor) as in DIP Changeover Kits
07 = Octoloader Motor/Z Motor/Shuttle
Motor as in Plunge to Board Change Kits
0092
Full Tube 1000s
30
30 to 39
Sets the 1000s digit for number of devices constituting a
full tube, in ASCII digits.
0093
Full Tube 100s
30
30 to 39
Set the 100s digit for number of devices constituting a
full tube, in ASCII digits.
0094
Full Tube 10s
35
30 to 39
Set the 10s digit for number of devices constituting a full
tube, in ASCII digits.
0095
Full Tube 1s
30
30 to 39
Set the 1s digit for number of devices constituting a full
tube, in ASCII digits.
0096
Test Sol Delay
10
00 to FF
This delay allows “settling” time for the DUT, eliminating
any bouncing motion in the test site before the test
contacts are turned on. Counts down in HEX in 10
millisecond steps. A
PPLIES TO
DIP
AND OTHER
“
NON
-
PLUNGE
”
STYLE KITS
.
0097
Start Test Delay
01
00 to FF
Time delay for the test contacts to close before the
handler sends a start test signal to the tester. Allows
the test contacts to fully close before issuing a start
pulse. Counts down in HEX in 1 millisecond steps.
0098
Start Pulse Width
14
00 to FF
Adjusts the start test pulse width. This is allowed to
provide flexibility in interfacing between the handler and
tester/programmers. Counts down in HEX in 1
millisecond steps.
0099
FF