General Interface Options and Set Up

Accessing a Handler Control Interface:

When the handler powers up, you will be given the opportunity to, PICK INTERFACE? If you press the
[Enter] button, the previously selected interface (or default interface, if RAM was cleared) will be selected.
Listed below are the standard interfaces currently supplied with the handler. N

OTE

: New interfaces are

added to the handler from time to time. Please contact E

XATRON

for updates as required. Our toll-free

telephone number is: 1-800-EXA-TRON.

From

“PICK INTERFACE?” displayed on the front panel:

[1] Key

Sets the handler to use "HANDLER PORT"

[2] Key

Sets the handler to use “EXATRON SUPER”

[3] Key

Sets the handler to use “H P RS-232”
[

NOTE

:

FOR

LABEL

/

TEST

,” “

LABEL ONLY

,”

AND

TEST ONLY

OPTIONS

,

PLEASE REFER

TO THE MODEL

3000

B

-

L USER

S MANUAL

.]

[4] Key

Sets the handler to use “PROGRAM RS-232”

[5] Key

Sets the handler to use “EXATRON RS-232”

[Enter] Key Sets your choice into the handler.
[Clear] Key Rejects selection and returns to PICK INTERFACE?.

General Interface RAM Selections:

Listed below are addresses in the handler’s battery backed-up RAM which may be edited to fine tune the
handler for your specific programmer/tester and sorting requirements when using either the Handler Port
(parallel) or the RS-232 serial port. These addresses are not part of the standard power-up selections
and may be modified only by “Changing The RAM,” as described in the Handler Set-Up Chapter of
this manual.

Interface Type: Address 00D2

This address allows the user to set the default interface to be used by the handler. The following table
lists available settings:

data setting 21

= EXATRON SUPER

data setting 23

= PROGRAM RS-232

data setting 24

= LASER ONLY KIT [

MODEL 5000 ONLY

.]

data setting 25

= EXATRON RS-232

data setting 26

= HANDLER PORT

data setting 27

= LOW GOING PULSE [

USES SPECIAL PAL A89

-

2LP

.]

data setting 28

= H P RF RS-232

Start Test Delay: Address 0097

For DIP devices only, this delay adds "settling" time to the DUT. The delay allows the DUT more time to
come to rest in the test site before the contacts close. The delay counts down in HEX, in 1 millisecond
steps.