Exatron 3000B

www.exatron.com

3-9

Chapter 3 Interface Info

Handler Port Interface

T

HE

H

ANDLER

P

ORT INTERFACE USES SIMPLE

TTL-

COMPATIBLE SIGNALS TO CONTROL THE HANDLER

. This

parallel port interface utilizes the 24 pin “D” connector on the side of the handler. It has been designed
to be compatible with “MCT-type” tester control interfaces.

The H

ANDLER

P

ORT

interface uses the addresses 00C0 through 00C7 for tester sort to output bin and

address 00BC for double test on/off selection. Please refer to the General Interface RAM Selections
section at the beginning of this chapter for further details.

Handler Port Pin Out:

Sort Input 1

Pin 1

Pin 13

Input 9, End of

Test

’

Sort Input 2

Pin 2

Pin 14

Not Used

Sort Input 3

Pin 3

Pin 15

Not Used

Sort Input 4

Pin 4

Pin 16

Not Used

Sort Input 5

Pin 5

Pin 17

Output 8

Sort Input 6

Pin 6

Pin 18

Output 7

Sort Input 7

Pin 7

Pin 19

Output 6

Sort Input 8

Pin 8

Pin 20

Output 5

2

nd

Start

Pin 9

Pin 22

Output 4

Output 1, Start

Test: Pulse

Pin 10

Pin 22

Output 2, Start

Test: Level

Handler

Vcc, +5 VDC

Pin 11

Pin 23

Handler

Vcc, +5 VDC

Handler

Ground

Pin 12

Pin 24

Handler

Ground

’

S

PECIAL

PAL R

EQUIRED

FIGURE 3-1

A

HANDLER INTERFACE PORTS DETAIL
OPTIONAL OPTO ISOLATION PORT
SEE 5000-D76 FOR DETAILS
MATING CONNECTOR T&B #609-2030

Sort 1 1
Sort 2 2
Sort 3 3
Sort 4 4
Sort 5 5
Sort 6 6
Sort 7 7

EOT 8

2

nd

Start 9

Start Test Pulse 10

Handler Vcc +5VDC 11
Tester Ground 12

13 Not

Used

14 Not

Used

15 Not

Used

16 Not

Used

17 Output

8

18 Output

7

19 Output

6

20 Output

5

21 Output

4

22 Start Test Level
23 Handler

Vcc+5VDC

24 Tester

Ground

NOTE: NEVER CONNECT
OPTO GROUND TO
HANDLER GROUND OR
OPTO Vcc TO HANDLER
Vcc