Explore Scientific 7-in-1 Sensor for 7-in-1 Wi-Fi Weather Station User Manual
Page 30
![background image](https://www.manualsdir.com/files/875018/content/doc030.png)
30
Date display
DD / MM or MM / DD
Time synchronize method
Through Internet time server to synchronize the UTC
Weekday languages
EN / DE / FR / ES / IT / NL / RU
Time Zone
+13 ~ -12 hour
DST
AUTO / OFF
Barometer Display & Function Specification
Note:
The following details are listed as they are displayed or operate on the console.
Barometer unit
hPa, inHg and mmHg
Measuring range
540 ~ 1100hPa (relative setting range 930 ~ 1050hPa)
Accuracy
(700 ~ 1100hPa ± 5hPa) / (540 ~ 696hPa ± 8hPa)
(20.67 ~ 32.48inHg ± 0.15inHg) / (15.95 ~ 20.55inHg ±
0.24inHg)
(525 ~ 825mmHg ± 3.8mmHg) / (405 ~ 522mmHg ± 6mmHg)
Typical at 25°C (77°F)
Resolution
1hPa / 0.01inHg / 0.1mmHg
Weather forecast
Sunny / Clear, Slightly Cloudy, Cloudy, Rainy, Rainy / Stormy
and Snowy
Display modes
Current
Memory modes
Historical data of past 24 hours, daily Max / Min
Alarm
Pressure change alert
Indoor / Outdoor Temperature Display & Function Specification
Note:
The following details are listed as they are displayed or operate on the console.
Temperature unit
°C and °F
Display range
Indoor:-40 ~ 70°C(-40 ~ 158°F), Outdoor:-40 ~ 80(-40 ~
176°F)
Outdoor Accuracy
55 ~ 60°C ± 0.5°C (131 ~ 140°F ± 0.9°F)
10 ~ 55°C ± 0.4°C (50 ~ 131°F ± 0.7°F)
-20 ~ 10°C ± 1.3°C (-4 ~ 50°F ± 2.3°F)
-40 ~ -20°C ± 1.9°C (-40 ~ -4°F ± 3.4°F)
Resolution
°C / °F (1 decimal place)
Display modes
Current
Memory modes
Historical data of past 24 hours, daily Max / Min
Alarm
Hi / Lo temperature alert
Indoor / Outdoor Humidity Display & Function Specification
Note:
The following details are listed as they are displayed or operate on the console.
Humidity unit
%
Display range
1 ~ 99%
Indoor Accuracy
20~39% or 71~90% RH ±8%RH @ 25°C (77°F)
40~70% RH ±5%RH @ 25°C (77°F)
Outdoor Accuracy
1 ~ 20% RH ± 6.5% RH @ 25°C (77°F)
21 ~ 80% RH ± 3.5% RH @ 25°C (77°F)
81 ~ 99% RH ± 6.5% RH @ 25°C (77°F)
Resolution
1%
Display modes
Current
Memory modes
Historical data of past 24 hours, Max / Min
Alarm
Hi / Lo Humidity Alert