Mounting the unit, Tabletop placement, Rack mounting – Extron electronic Fiber Optics Fox 4G DA8 User Manual
Page 8: Ul guidelines, Mounting instructions, Tabletop placement -2 rack mounting -2, Ul guidelines -2 mounting instructions -3, Installation and operation
FOX 4G DA8 • Installation and Operation
Installation and Operation
FOX 4G DA8 • Installation and Operation
2-2
2-3
Mounting the Unit
C
Installation and service must be performed by
authorized personnel only.
The 1U high, half-rack width unit can be placed on a tabletop,
mounted on a rack shelf, or mounted under or through a desk or
other furniture.
Tabletop placement
Affix the four included rubber feet to the bottom of the unit and
place it in any convenient location.
Rack mounting
UL guidelines
The following Underwriters Laboratories (UL) guidelines
pertain to the installation of the FOX 4G DA8 into a rack
(figure 2-1).
1
.
Elevated operating ambient
— If installed in a closed
or multi-unit rack assembly, the operating ambient
temperature of the rack environment may be greater
than room ambient. Therefore, consider installing the
equipment in an environment compatible with the +122 °F
(+50 °C) maximum ambient temperature (Tma) specified
by Extron
2
.
Reduced air flow
— Installation of the equipment in a rack
should be such that the amount of air flow required for
safe operation of the equipment is not compromised.
3
.
Mechanical loading
— Mounting of the equipment in
the rack should be such that a hazardous condition is not
achieved due to uneven mechanical loading.
4
.
Circuit overloading
— Consideration should be given to
the connection of the equipment to the supply circuit and
the effect that overloading of the circuits might have on
overcurrent protection and supply wiring. Appropriate
consideration of equipment nameplate ratings should be
used when addressing this concern.
5
.
Reliable earthing (grounding)
— Reliable earthing
of rack-mounted equipment should be maintained.
Particular attention should be given to supply connections
other than direct connections to the branch circuit (such as
the use of power strips).
Mounting instructions
For optional rack mounting, mount the 1U high, half rack width
unit on either of the following rack shelves:
• RSU 129 9.5" 1U universal rack shelf kit (part #60-190-01)
(figure 2-1)
• RSB 129 9.5" 1U basic rack shelf (part #60-604-01)
Use 2 mounting holes on
opposite corners.
(2) 4-40 x 3/16"
Screws
NOTE:
Using screws longer
than 3/16” will damage the
unit and void the warranty.
1U Universal Rack Shelf
Front false
faceplate
uses 2
screws.
1/2 Rack Width Front False
Faceplate
Figure 2-1 — Mounting the unit on a standard rack shelf
1
.
If installed, remove the feet from the bottom of the unit.
2
.
Mount the unit on either the left or right side of the shelf,
using two 4-40 x 3/16" screws in opposite (diagonal)
corners to secure the unit to the shelf.
3
.
Install a false faceplate or another unit onto the rack shelf.
4
.
Insert the shelf into the rack, aligning the holes in the shelf
with those of the rack.
5
.
Secure the shelf to the rack using the supplied machine
screws.