beautypg.com

Mounting the unit, Tabletop placement, Rack mounting – Extron electronic Fiber Optics Fox 4G DA8 User Manual

Page 8: Ul guidelines, Mounting instructions, Tabletop placement -2 rack mounting -2, Ul guidelines -2 mounting instructions -3, Installation and operation

background image

FOX 4G DA8 • Installation and Operation

Installation and Operation

FOX 4G DA8 • Installation and Operation

2-2

2-3

Mounting the Unit

C

Installation and service must be performed by

authorized personnel only.

The 1U high, half-rack width unit can be placed on a tabletop,

mounted on a rack shelf, or mounted under or through a desk or

other furniture.

Tabletop placement

Affix the four included rubber feet to the bottom of the unit and

place it in any convenient location.

Rack mounting

UL guidelines

The following Underwriters Laboratories (UL) guidelines

pertain to the installation of the FOX 4G DA8 into a rack

(figure 2-1).
1

.

Elevated operating ambient

— If installed in a closed

or multi-unit rack assembly, the operating ambient

temperature of the rack environment may be greater

than room ambient. Therefore, consider installing the

equipment in an environment compatible with the +122 °F

(+50 °C) maximum ambient temperature (Tma) specified

by Extron

2

.

Reduced air flow

— Installation of the equipment in a rack

should be such that the amount of air flow required for

safe operation of the equipment is not compromised.

3

.

Mechanical loading

— Mounting of the equipment in

the rack should be such that a hazardous condition is not

achieved due to uneven mechanical loading.

4

.

Circuit overloading

— Consideration should be given to

the connection of the equipment to the supply circuit and

the effect that overloading of the circuits might have on

overcurrent protection and supply wiring. Appropriate

consideration of equipment nameplate ratings should be

used when addressing this concern.

5

.

Reliable earthing (grounding)

— Reliable earthing

of rack-mounted equipment should be maintained.

Particular attention should be given to supply connections

other than direct connections to the branch circuit (such as

the use of power strips).

Mounting instructions

For optional rack mounting, mount the 1U high, half rack width

unit on either of the following rack shelves:
• RSU 129 9.5" 1U universal rack shelf kit (part #60-190-01)

(figure 2-1)

• RSB 129 9.5" 1U basic rack shelf (part #60-604-01)

Use 2 mounting holes on
opposite corners.

(2) 4-40 x 3/16"
Screws

NOTE:

Using screws longer

than 3/16” will damage the
unit and void the warranty.

1U Universal Rack Shelf

Front false
faceplate
uses 2
screws.

1/2 Rack Width Front False
Faceplate

Figure 2-1 — Mounting the unit on a standard rack shelf

1

.

If installed, remove the feet from the bottom of the unit.

2

.

Mount the unit on either the left or right side of the shelf,

using two 4-40 x 3/16" screws in opposite (diagonal)

corners to secure the unit to the shelf.

3

.

Install a false faceplate or another unit onto the rack shelf.

4

.

Insert the shelf into the rack, aligning the holes in the shelf

with those of the rack.

5

.

Secure the shelf to the rack using the supplied machine

screws.