Step 1
If the power amplifier is powered on, be sure that power to the amplifier is turned off first.
N
Adjust the audio level to - = (full attentuation) prior to the amplifier being powered back up in Step 5. See
"Rear Panel
Features and Operation" in chapter 3 of the user’s manual.
Turn off all other equipment and disconnect the power cords. Verify that the amplifier is disconnected from the power source
before proceeding.
Step 2
For diagrams of typical application examples, see "Application Examples" in chapter 2. For further mounting instructions, see
"Mounting the XPA 1002 and XPA 2001" in chapter 2 of the user’s manual.
Step 3
Wire input to the amplifier's input 3.5 mm connectors, as shown in the following illustration. See "Rear Panel Features and
Operation" in chapter 3 of the user’s manual.
N
The XPA 1002’s output power can be effectively doubled by using only one input channel and bridging the output. The
XPA 1002 outputs 200 watts @ 8 ohms or 120 watts @ 16 ohms in bridged mode. See “Bridged mode output” in chapter 3
of the user’s manual for wiring instructions when bridging the XPA 1002
Do not tin the wires!
Balanced Stereo Input
Tip
Ring
Tip
Ring
L
R
Sleeves
Unbalanced Stereo Input
Tip
Sleeve
Sleeve
Tip
L
R
Balanced Mono Input
(high impedance)
Tip
Ring
L
R
Sleeve
Unbalanced Mono Input
Tip
Sleeve
L
R
N
For mono input on the XPA 2001, only the left channel needs to be wired; no jumpering to the right channel is needed.
Step 4
Wire speakers to the amplifier’s output connector using the included
4-pole (XPA 1002) or 2-pole (XPA 2001-70V and XPA 2001-100V) screw
lock plug as shown to the right. See “Rear Panel Features and Operation”
in chapter 3 of the user’s manual.
Step 5
Reconnect all power cords and switch on all other equipment before powering up the power amplifier. The amplifier must be
powered up last. The amplifier’s front panel power LED should light green.
Step 6
Adjust the audio level using the rear panel adjustment screws as shown to
the right. See “Rear Panel Features and Operation” in chapter 3.
Step 7
The limiter/protect and signal LEDs located on the front and rear panels should be checked if problems are encountered. See
“Front Panel Features and Operation” in chapter 3.
Step 8
The 3.5 mm 5-pin captive screw remote control connector (shown to the right) is used
to control volume and standby mode through contact closure. Standby mode
turns off all output, although the XPA is still receiving power. See
“Front Panel Features and Operation” in chapter 3.
68-1351-50
Rev. A
02 09
Extron
USA - West
Headquarters
+800.633.9876
Inside USA / Canada Only
+1.714.491.1500
+1.714.491.1517 FAX
Extron
USA - East
+800.633.9876
Inside USA / Canada Only
+1.919.863.1794
+1.919.863.1797 FAX
Extron
Europe
+800.3987.6673
Inside Europe Only
+31.33.453.4040
+31.33.453.4050 FAX
Extron
Asia
+800.7339.8766
Inside Asia Only
+65.6383.4400
+65.6383.4664 FAX
Extron
Japan
+81.3.3511.7655
+81.3.3511.7656 FAX
Extron
China
+400.883.1568
Inside China Only
+86.21.3760.1568
+86.21.3760.1566 FAX
Extron
Middle East
+971.4.2991800
+971.4.2991880 FAX
1
2
OUTPUT
XPA 1002
XPA 2001-70V
OUTPUT
70V
XPA 2001-100V
OUTPUT
100V
LEVEL
0
XPA 2001
LEVEL
1
2
0
0
XPA 1002
1
2 3
4 5
STANDBY
VOL/MUTE
10V
50 mA
MUTE
VOLUME
GND
10K OHMS
2K OHMS
MAX
2
VOL/MUTE
3
1
10 V
MIN
1
2 3
STANDBY
MUTE SWITCH
VOL/MUTE
10V
50 mA