beautypg.com

Data format specification, English, Operation command (pc → this product) – Elmo P100 User Manual

Page 41: Response data format (this product → pc)

background image

90

ABOUT

RS-232C

ENGLISH

Data Format Specification

This command is executed in the form of 1-command/1-packet. The next command is not
accepted until the previous processing is completed.
• The communication command always starts with STX (Start of Text), and ends with ETX (End

of Text).

• If the communication format of command name is wrong, NAK (Negative Acknowledge)

will be sent from this product as a result of failing to receive correctly.

• When communication format is received correctly, this product sends ACK (Normal

Acknowledge).

Operation Command (PC This product)

Each operation command is executed in ASCII code, and transmitted in a set of 7 bytes as
follows:

S

T

X

E

T

X

Command

(PC)

(This product)

→ ACK

Data

Parameter

S

T

X

Posi/

Nega

Color/

B&W

Camera Mode

/SD Mode

Display

Flickerless

E

T

X

Input

selection

Lighting

Pause

Gamma

selection

Monitor

output

USB

Mode

S

T

X

Image

rotation

Edge

effect

White

balance

Text

E

T

X

Iris

mode

V

56H

H

48H

N

4EH

S

T

X

E

T

X

20H

S

T

X

E

T

X

20H

S

T

X

E

T

X

Response Data Format (This product PC)

All response data is transmitted as ASCII code, corresponding to the parameters in the
operation command table.
• Status 0

• Status 2

ROM Ver0 (MASTER)

ROM Ver1 (SLAVE)

V

56H

H

48H

N

4EH

S

T

X

E

T

X

ROM Ver2 (LENS)

V

56H

H

48H

N

4EH

S

T

X

E

T

X

ROM Ver3 (MAIN) . . . Upper 6 bytes