beautypg.com

4 pre-installation check list, Pre-installation check list, 4pre-installation check list – Bosch VG4-A-PSU1 Power Supply Unit for CCTV Cameras User Manual

Page 10

background image

10

en | Pre-installation Check List

Power Supply Units (AUTODOME7000, MIC7000

cameras)

2020-10 | |

Installation Manual

Bosch Security Systems, Inc.

4

Pre-installation Check List

!

Caution!

Installation must be made by qualified personnel and conform to ANSI/NFPA 70 (the National
Electrical Code

®

(NEC)), Canadian Electrical Code, Part I (also called CE Code or CSA C22.1),

and all applicable local codes. Bosch Security Systems accepts no liability for any damages or
losses caused by incorrect or improper installation.

1. Determine the location and distance for the power supply box based on its voltage and
current consumption.

Power

115/230 VAC

Copper Wire

To comply with local codes.

Maximum Wire Distances, Power Supply to AUTODOME 600 Series Camera

24 V to AUTODOME camera

VA / Watts

14 AWG

(2.5 mm)

16 AWG

(1.5 mm)

18 AWG

(1.0 mm)

AUTODOME 600, Indoor

27 / 15

129 m (422 ft)

81 m  (265 ft)

51 m (167 ft)

AUTODOME 600, Outdoor

55 / 51

63 m (207 ft)

40 m (130 ft)

25 m (82 ft)

Maximum Wire Distances from Power Supply to AUTODOME 7000 HD

24 V to AUTODOME

7000

VA / Watts

14 AWG
(2.5 mm)

16 AWG
(1.5 mm)

18 AWG
(1.0 mm)

HD models with IVA, Indoor

35 / 19

99 m (325 ft)

62 m (205 ft)

39 m (129 ft)

HD models with IVA, Outdoor

60 / 55

58 m (190 ft)

36 m (119 ft)

23 m (75 ft)

2. Use only UL listed liquid-tight strain reliefs for conduits to the power supply box to ensure
that water cannot enter the box. You must use water tight conduits and fittings to meet NEMA
4 standards.

Notice!

Power and I/O cabling must be routed separately inside different permanently earthed metal
conduits.

3. Install all rough wiring, including: power, control, video coax, alarms I/O, relay I/O, and fiber
optic cabling. For video and control protocol methods for AUTODOME cameras, refer to

Video

and Control Cables (AUTODOME VG5-600 Camera Models ONLY), page 20.
4.

For an analog AUTODOME camera only

: If you plan to use the RS-232 or RS-485 protocol

to control the camera, refer to

Controlling the AUTODOME via the RS232 Protocol, page 24,

or

Controlling the AUTODOME via the RS-485 Protocol, page 25, for instructions on

configuring the camera to accept these protocols.