beautypg.com

3. other problems – Eizo FlexScan EV3895FX-BK 37.5" 24:10 Ultrawide Curved IPS Monitor (Black) User Manual

Page 39

background image

6-3. Other Problems

Problem

Possible cause and remedy

1. The Setting menu does not

appear.

Check whether the switch operation lock function is active (see

“Key

Lock” (page 35)

).

2. Cannot select items in the Setting

menu.

Items that are displayed with gray text cannot be changed.

3. No audio output.

Check whether volume is set to 0.

Check the PC and audio playback software to see whether they are

configured correctly.

When using PbyP display, check the settings for “Sound Selection

(PbyP)” (see

“Sound Selection (PbyP)” (page 24)

).

4. USB devices connected to the

monitor do not work / the docking

station function cannot be used.

Check whether the USB cable is correctly connected between the

PC and the monitor.

When two or three PCs are connected to one monitor, check

whether the correct USB upstream port is enabled (see

“4-3. Linking

the Input Signal and USB Port” (page 31)

).

Check whether the USB cable is correctly connected between the

peripheral and the monitor.

Try using a different USB port on the monitor.

Try using a different USB port on the PC.

Reboot the PC.

When “Compatibility Mode” is set to “Off” in the “Administrator

Settings” menu and the power of the monitor is turned off, devices

connected to the USB downstream port are not operational. Change

the setting for “Compatibility Mode” to “On” (see

“Compatibility

Mode” (page 34)

).

When “USB” is set to “Off” in the “Administrator Settings” menu,

peripheral devices connected to the USB port cannot be used. Set

“USB” to “On” (see

“USB” (page 35)

).

In the following cases, the LAN port cannot be used.

- When “Ethernet” is set to “Off” in the “Administrator Settings”

menu. Set “Ethernet” to “On” (see

“Ethernet” (page 35)

).

- When USB-C connection is not used.

- When the OS of the PC is not supported (see

“8-2. Specifications”

(page 46)

).

If the peripheral devices work correctly when they are directly

connected to the PC, contact your local EIZO representative.

Depending on the USB host controller you are using, the connected

USB device may not be recognized properly. Update to the latest

USB driver provided by the manufacturer, or connect the monitor to

the USB 2.0 port.

Check the PC’s BIOS setting for USB when using Windows. (See

the manual of the PC for details.)

5.

Power indicator is flashing

orange and white.

This symptom may occur when the PC is connected to the

DisplayPort connector. Use a signal cable recommended by us for

the connection. Turn the monitor off and on.

Check the connection and condition of the USB devices connected

to the monitor.

Turn off the main power switch on the rear side of the monitor, and

then turn it on again.

6. Even when the mouse or

keyboard are used, the computer

does not return from sleep.

Turn the setting “On” for “Compatibility Mode” on the “Administrator

Settings” menu (see

“Compatibility Mode” (page 34)

).

39

Chapter 6 Troubleshooting