Other flash units – Nikon D7200 body User Manual
Page 339
315
❚❚ Other Flash Units
The following flash units can be used in non-TTL auto and
manual modes.
Flash unit
SB-80DX,
SB-28DX,
SB-28, SB-26,
SB-25, SB-24
SB-50DX
1
SB-30, SB-27
2
,
SB-22S, SB-22,
SB-20, SB-16B,
SB-15
SB-23,
SB-29
3
,
SB-21B
3
,
SB-29S
3
Flash mode
A
Non-TTL auto
✔
—
✔
—
M
Manual
✔
✔
✔
✔
G
Repeating flash
✔
—
—
—
REAR Rear-curtain sync
4
✔
✔
✔
✔
1 Select mode P, S, A, or M, lower built-in flash, and use optional flash unit only.
2 Flash mode is automatically set to TTL and shutter-release is disabled. Set flash unit to A (non-
TTL auto flash).
3 Autofocus is available with AF-S VR Micro-Nikkor 105mm f/2.8G IF-ED and AF-S Micro NIKKOR
60mm f/2.8G ED lenses only.
4 Available when camera is used to select flash mode.
A
Metering
The metering areas for FV lock when using optional flash unit are as
follows:
Flash unit
Flash mode
Metered area
Stand-alone flash
unit
i-TTL
4-mm circle in center of frame
AA
Area metered by flash
exposure meter
Used with other flash
units (Advanced
Wireless Lighting)
i-TTL
Entire frame
AA
Area metered by flash
exposure meter
A (master flash)