If line-of-sight is not achieved, levels will be degraded. The Fresnel2 zone
(shown in the following examples) requires freedom from any obstructions.
5.3.2 Central Office M-Lower Mader Tank
Central Office
Lower Mader Tank (M)
Elevation (feet)
687.34
1007.21
Latitude
34 17 09.00 N
34 17 03.00
Longitude
118 48 47.00 W
118 47 08.00 W
True Azimuth (degrees)
94.17
274.18
Vertical Angle (degrees)
2.38
-2.39
Antenna Model
A2410NJ-DY
A2414NJ-DY
Antenna Height (feet)
18.00
45.00
Antenna Gain (dBi)
10.00
14.00
(dbm) 7.85
11.85
TX Line Type
C40M40-40-040
CVX540-40-100
TX Line Length (feet)
40.0
100.0
Tx Line Unit Loss (dB/100 feet)
6.70
2.20
Tx Line Loss (dB)
2.68
2.20
Connector Loss (dB)
0.40
0.40
Miscellaneous Loss (dB)
1.50
1.50
Frequency (MHz)
2400.0
Polarization Vertical
Path Length (mi)
1.58
Free Space Loss (dB)
108.16
Net Path Loss (dB)
92.84
92.84
Radio Model
RLX-IH
RLX-IH
Tx Power (Watts)
0.20
0.20
(dBm) 23.00
23.00
Effective Radiated Power
0.42 Watts
1.19 Watts
(dBm) 6.27
30.75
RX Sensitivity (µv)
11.21
11.21
Central Office
Lower Mader Tank (M)
(dBm) -86.00
-86.00
RX Signal (µv)
71.99
71.99
(dBm) -69.84
-69.84
RX Field Strength (µv/m)
3012.58
1798.62
Fade Margin (dB)
16.16
16.16
Notes
Line of Sight (LoS): Required for proper signal strength. Line of Sight means you
can see the location at which you are trying to get an RF signal to. If the location
is 5 miles or more, binoculars or a telescope can be used.