5.1.2 Hardware

Specifications

Specification Description

Dimensions

Standard 1769 Single-slot module

Current Load

800 mA max@ 5 VDC

Power supply distance rating of 2 (L43 and L45
installations on first 2 slots of 1769 bus)

Operating Temp.

0 to 60°C (32 to 140°F)

Storage Temp.

-40 to 85°C (-40 to 185°F)

Relative Humidity

5% to 95% (non-condensing)

LED Indicators

Battery and Module Status

Application Status

Serial Port Activity

CFG Port Activity

CFG Port (CFG)

RJ45 (DB-9F with supplied cable)

RS-232 only

No hardware handshaking

App Ports (P1,P2) (Serial modules)

RS-232 or RS-422 (jumper selectable)

RJ45 (DB-9F with supplied cable)

RS-232 handshaking configurable

500V Optical isolation from backplane

Shipped with Unit

RJ45 to DB-9M cables for each port

6-foot RS-232 configuration Cable

5.1.3 Functional

Specifications

ƒ Single-slot, CompactLogix I/O compatible
ƒ Multiple modules can be placed in a rack up to the chassis power supply limit
ƒ While in 3964R with RK512 mode on PRT1 and PRT2, DB-SEND and DB-

FETCH instructions can be initiated from the CompactLogix processor or
received by the communications partner

ƒ While in 3964R without RK512 mode on PRT1 and PRT2, data can be sent

from the CompactLogix processor or be received from the communications
partner

ƒ The maximum transfer size is 512 bytes in any mode
ƒ Data byte swapping can be configured to adjust to a different word format
ƒ While in 3964R with RK512 mode on PRT1 and PRT2, evaluation of the

header information DB (data block), DW (data word) and coordination bytes 9
and 10 is possible

ƒ Communication activity and diagnostics are available through LEDs and

acknowledgment telegrams