Ladder Logic

MVI69-S3964R ♦ CompactLogix or MicroLogix Platform

Siemens 3964R Protocol

ProSoft Technology, Inc.

Page 39 of 80

October 31, 2008

Click OK to continue.

4 Select the Request Packet Interval value for scanning the I/O on the module.

This value represents the minimum frequency the module will handle
scheduled events. This value should not be set to less than 1 millisecond.
Values between 1 and 10 milliseconds should work with most applications.

5 Save the module. Click OK to dismiss the dialog box. The Controller

Organization window now displays the module's presence. The following
illustration shows the Controller Organization window:

6 Copy the Controller Tags from the sample program.
7 Copy the User Defined Data Types from the sample program.
8 Copy the Ladder Rungs from the sample program.
9 Save and Download the new application to the controller and place the

processor in run mode.