beautypg.com

PLANET GS-4210-8P2S User Manual

Page 299

background image

User’s Manual of GS-4210 Series

TTL in seconds is based on the following rule:

(Transmission Interval * Holdtime Multiplier) ≤ 65536.

Therefore, the default TTL is 4*30 = 120 seconds.

Reinitialization Delay

When a port is disabled, LLDP is disabled or the switch is rebooted a LLDP

shutdown frame is transmitted to the neighboring units, signaling that the LLDP

information isn't valid anymore. Tx Reinit controls the amount of seconds

between the shutdown frame and a new LLDP initialization. Valid values are

restricted to 1 - 10 seconds.

Transmit Delay

If some configuration is changed (e.g. the IP address) a new LLDP frame is

transmitted, but the time between the LLDP frames will always be at least the

value of Transmit Delay seconds. Transmit Delay cannot be larger than 1/4 of

the Transmission Interval value. Valid values are restricted to 1 - 8192 seconds.

This attribute must comply with the rule:

(4 * Delay Interval) ≤Transmission Interval

LLDP-MED Fast Start

Repeat Count

Configures the amount of LLDP MED Fast Start LLDPDUs to transmit during the

activation process of the LLDP-MED Fast Start mechanisim.

Range: 1-10 packets;

Default: 3 packets

The MED Fast Start Count parameter is part of the timer which ensures that the

LLDP-MED Fast Start mechanism is active for the port. LLDP-MED Fast Start is

critical to the timely startup of LLDP, and therefore integral to the rapid availability

of Emergency Call Service.

Buttons

: Click to apply changes.

Figure 4-12-2 LLDP Global Config Page Screenshot

299

This manual is related to the following products: