Appendix c: error messages, Start-up error messages, Drive check error messages – Avago Technologies eXtremeRAID 3000 User Manual
Page 55: Appendix c, Extremeraid 3000 error messages

Manual No. DB11-000033-00
C-1
Appendix C
eXtremeRAID 3000
Error Messages
☛
Note
The firmware you are using may have these messages
turned off. However, they are listed here for your
reference.
Start-up Error Messages
The BIOS looks for any initialization message posted by the firmware during
the start-up sequence. If a message is found, one of the following errors
displays on screen and the installation process aborts.
EXR3000 fatal error--Memory test failed!
EXR3000 fatal error--Command interface test failed!
EXR3000 hardware error--Run Diagnostics to pinpoint
error
EXR3000 firmware checksum error--Reload firmware
EXR3000 Mismatch between NVRAM & Flash EEPROM
configurations!
Drive Check Error Messages
If mismatches are found, then, the BIOS prints out the following:
eXtremeRAID 3000 Configuration Checksum error--Run
configuration utility!
If the firmware detects that during the last power cycle the system was turned
off abruptly leaving some incomplete write operations, the following
message appears:
Recovery from mirror race in progress
WARNING: Dead SCSI devices (Channel Target) : x:y
The following messages may also appear:
EXR3000 cannot recover from Mirror Race!
Some system drives are inconsistent!