eXtremeRAID 3000 Installation Guide

SCSI Drive Preparation

To prepare the drives for installation, follow these steps:

1. Remove any terminators attached to the drive or set any drive

termination jumpers to the disabled position.

2. Set the SCSI IDs on the drives.

3. Enable term power on the drives.

Refer to the drive manual for specific information about drive configuration
settings.

Do Not Mix Narrow and Wide SCSI Drives

Note

There is only one internal SCSI channel available to
connect SCSI devices. It is recommended not to mix
narrow and wide SCSI devices on this channel.
In some cases, this may cause signal degradation.

Mixing LVD with Single-ended Drives

If LVD capable drives are installed on a channel with single-ended devices,
all drives on the channel will operate as if they were single-ended devices.
This will also limit the bus length to the single-ended bus length specified in
Table 2-2.

No Fibre Termination

Note

Fibre channels do not require termination; therefore,
no manual termination settings are needed. The Fibre
Channel Cabinet

1

automatically handles Fibre

channel setup requirements.

1. Check the manufacturer’s documentation for the Fibre Channel

Cabinet that you are using.