Amprobe, Multitest2000, Analyzer and aux functions – Amprobe Multitest-2000 Continuity-Tester User Manual
Page 136
AMPROBE
MULTITEST2000
14.1.2. ANALYZER and AUX functions
VOLTAGE MEASUREMENT – SINGLE PHASE SYSTEM (AUTORANGE)
Range [V]
Resolution [V]
Accuracy
Input Impedance
15
÷ 310V
0.2V
310
÷ 600V
0.4V
±(0.5% Reading+2digit)
300k
Ω (Phase-Neutral)
300k
Ω (Phase-Phase)
VOLTAGE SAG AND SURGE DETECTION – SINGLE PHASE SYSTEM (MANUAL RANGE)
Range [V]
Resolution
(Voltage)
Resolution
(Time)
Accuracy
(Voltage)
Accuracy (rif. 50Hz)
(Time)
Input Impedance
15
÷ 310V
0.2V
30
÷ 600V
0.4V
10ms (½ period)
±(1.0% Reading+2digit)
± 10ms (½ period)
300k
Ω (Phase-Neutral)
300k
Ω (Phase-Phase)
CURRENT MEASUREMENT – SINGLE PHASE SYSTEM (AUTORANGE)
Range [V]
Resolution [mV]
Accuracy Input
Impedance
Overload Protection
0.005
÷0.26V 0.1
0.26
÷1V 0.4
±(0.5% Reading+2digit)
200k
Ω 5V
(*): Example: with a 1000A/1V full scale clamp , the instrument detect only current higher than 5A
POWER MEASUREMENT – SINGLE PHASE SYSTEM (AUTORANGE)
Quantity Range
Accuracy
Resolution
ACTIVE POWER
0
÷ 999.9W
1
÷ 999.9kW
1
÷ 999.9MW
1000
÷ 9999MW
0.1W
0.1kW
0.1MW
1MW
REACTIVE POWER
0
÷ 999.9VAR
1
÷ 999.9kVAR
1
÷ 999.9MVAR
1000
÷ 9999MVAR
0.1VAR
0.1kVAR
0.1MVAR
1MVAR
APPARENT POWER
0
÷ 999.9VA,
1
÷ 999.9kVA,
1
÷ 999.9MVA
1000
÷ 9999MVA
0.1VA
0.1kVA
0.1MVA
1MVA
ACTIVE ENERGY
(Classe2 EN61036)
0
÷ 999.9Wh,
1
÷ 999.9kWh,
1
÷ 999.9MWh
1000
÷ 9999MWh
0.1Wh
0.1kWh
0.1MWh
1MWh
REACTIVE ENERGY
(Classe3 IEC1268)
0
÷ 999.9VARh,
1
÷ 999.9kVARh,
1
÷ 999.9MVARh
1000
÷ 9999MVARh
±(1.0%Reading+2digit)
0.1VARh
0.1kVARh
0.1MVARh
1MVARh
Cos
ϕ MEASUREMENT – SINGLE PHASE SYSTEM
Cos
ϕ
Resolution
Accuracy [°]
0.20
0.6
0.50
0.7
0.80
0.01
1.0
VOLTANGE AND CURRENT HARMONICS MEASUREMENT – SINGLE PHASE SYSTEM
Range
Accuracy Resolution
DC – 25H
±(5% + 2 digit)
26H – 33H
±(10% + 2 digit)
34H – 49H
±(15% + 2 digit)
0.1V / 0.1A