Amprobe, Technical specifications, Multitest2000 – Amprobe Multitest-2000 Continuity-Tester User Manual
Page 134
AMPROBE
MULTITEST2000
14. TECHNICAL
SPECIFICATIONS
14.1. TECHNICAL
FEATURES
Accuracy is indicated as [% of reading + number of digits]. It refers to the following
atmospheric conditions: a temperature of 23°C ± 5°C with a relative humidity < 60%.
14.1.1. Safety Test functions
LOW
Ω: 200mA CONTINUITY TEST (AUTO, RT+, RT- MODE)
Range [
Ω] Resolution
[
Ω]
Accuracy(*)
0.01
ч 9.99
10.0
ч 99.9
0.01
0.1
±(2% Reading + 2 digit)
(*) After Test leads calibration
Test Current
> 200mA DC per R
≤5Ω (Test leads included)
Resolution for Test current:
1mA
Open Circuit Voltage
4V
≤ V0 ≤ 24V
M
Ω: INSULATION TEST
Test Voltage [V]
Range [M
Ω] Resolution
[M
Ω]
Accuracy
0.01
ч 9.99
0.01
10.0
ч 49.9
0.1
±(2% Reading + 2 digit)
50
50.0
÷ 99.9
0.1
±(5% Reading + 2 digit)
0.01
ч 9.99
0.01
10.0
ч 99.9
0.1
±(2% Reading + 2 digit)
100
100.0
÷ 199.9
0.1
±(5% Reading + 2 digit)
0.01
ч 9.99
0.01
10.0
ч 199.9
0.1
200
ч 249
1
±(2% Reading + 2 digit)
250
250
÷ 499
1
±(5% Reading + 2 digit)
0.01
ч 9.99
0.01
10.0
ч 199.9
0.1
200
ч 499
1
±(2% Reading + 2 digit)
500
500
÷ 999
1
±(5% Reading + 2 digit)
0.01
ч 9.99
0.01
10.0
ч 199.9
0.1
200
ч 999
1
±(2% Reading + 2 digit)
1000
1000
÷ 1999
1
±(5% Reading + 2 digit)
Open circuit Test Voltage
<1.3 x Nominal Test Voltage
Short Circuit Current
<6.0mA with 500V Test Voltage
Nominal Test Current
500V
>2.2mA with 230k
Ω
other
>1mA with 1k
Ω*Vnom
FREQUENCY
MEASUREMENT
Range [Hz]
Resolution [Hz]
Accuracy
47.0
÷ 63.6
0.1
±(0.1%Reading+1 digit)