DBP - Rev 6/93

Guide lines for connecting non-isolated AC supplies

Ground:

Control common

Motor chassis

Amplifier's heatsink

Do not ground:

Power common

(The power common is a hot point and any grounding will cause an input

rectifier failure).

Caution:

- If source of motor command is grounded, use amplifier's differential input.

Otherwise, a ground loop is created.