12
DBP - Rev 6/93
3.2 Analog input specification
Maximum input voltage:
- When R1 (470ohm) is inserted, the absolute value of the input voltage should be
less than 5V.
- When the absolute value is higher than 5V, R1(Kohm) = 2Vi-10 should be inserted.
The
µ
P reads always +5V.
Resolution of the digital conversion: 11 bit full scale.
Typical offset: 5 bits
470K
300
4700PF
4700PF
U1\10
VREF
4700PF
9
10
8
U8C
470k
18a
ANALOG
1
2
R1
*
470k
6
5
7
U8B
DIGITAL GND
470k
1000PF
20K
VREF
DIGITAL GND
300
4700PF
4700PF
U1\11
DIGITAL GND
20K
13
12
14
U8D
DIGITAL GND
10K
DIGITAL GND
INPUT
ANALOG INPUT