67

DBP - Rev 6/93

6.5.2 AC power wiring

AC

AC

AC

+Vs

DC power common

Control common

Heatsink

Fuse

Fuse

Fuse

A. Direct connection to the

three phase mains

B. External fuses are needed for 3U size only

DBP + O option

======================================================================

AC

AC

AC

+Vs

DC power common

Control common

Heatsink

Fuse

Fuse

Fuse

B. Using autotransformer with

Autotransformer

three phase mains

DBP + O option

A. External fuses are needed for 3U size only