D 150 – Essick Air AS20012 User Manual

Page 9

background image

AD OUTLET

E

E

A

Q

X

D

G

F

G

D

S

Q

W

R

C

J

J

N

P

B

B

A

L

M

M

E

E

N

Y

L

P

D

H

U

B

T

AD OUTLET

C

TOP VIEW

W

E

I

V

E

D

I

S

W

E

I

V

T

N

O

R

F

BLOWER

SECTION

AS OUTLET

AU OUTLET

* All measurements in inches.

D

45
45

48

1/4

48

1/4

60

1/4

H

100W

10012W

150W

15012W
20012W

WET

MODULE

NUMBER

AS/AD 100B
AS/AD 10012B
AS/AD 150B
AS/AD 15012B
AS/AD/AU 20012B

BLOWER

MODEL

NUMBER

CABINET

W

44
44
54
54

59

1/4

82
90

85

1/4

93

1/4

105

1/4

C

(AS)

13

19/32

13

19/32

16

13/16

16

13/16

18

11/16

A

DUCT

OPENING

B

21

3/4

21

3/4

26

7/8

26

7/8

31

3/4

21

3/4

21

3/4

26

7/8

26

7/8

31

3/4

U

(AD)

21

11/32

21

11/32

19

5/32

19

5/32

25

1/4

E

P

(AU)

11

5/8

11

5/8

10

11/16

10

11/16

14

1/4

N/A
N/A
N/A
N/A

24

29/32

DUCT

LOCATION

F

DRAIN

LOCATION

G

22

1/2

22

1/2

24

1/8

24

1/8

30

1/8

12

1/2

16

1/2

12

1/2

16

1/2

16

1/8

X

MEDIA

DIMENSION

Y

44

3/4

44

3/4

48
48
60

36

5/8

36

5/8

46

3/8

46

3/8

51

5/8

WET

MODULE

J

18

1/2

22

1/2

18

1/2

22

1/2

22

1/2

L

WATER

SERVICE

M

5

7/8

5

7/8

5

7/8

5

7/8

5

7/8

14

5/8

18

5/8

14

5/8

18

5/8

18

5/8

S

ELECTRIC

SERVICE

T

39

7/8

43

7/8

41

1/2

45

1/2

51

5/8

5

5/32

5

5/32

5

5/32

5

5/32

5

5/32

N

23

1/4

27

1/4

23

1/4

27

1/4

27

1/4

Q

SKID

LOCATIONS

R

4

3/4

4

3/4

4

3/4

4

3/4

4

3/4

42
42
52
52

57

1

/4

DIMENSIONAL DATA*

D 150

SIZING TABLES

SHEAVE SELECTION

MOTOR SPECIFICATIONS

SPECIFICATIONS

PERFORMANCE

Certified Air Delivery At .1" Increments Of External Static Pressure

(Inches Static Pressure Water Gauge)

2

7

9

10

12

11

6

5

4

3

1

OUTDOOR WET-BULB

LAT

GPH

LAT

GPH

LAT

GPH

LAT

GPH

85

95

105

115

OUTDOOR

DRY BULB

TEMP.

OUTDOOR WET-BULB

OUTDOOR WET-BULB

Performance shown is for installation type B - Free inlet, Ducted outlet. Power rating (BHP) does not include drive losses. Models AS/AD 150 include the affects of an 8 inch thick evaporative media on the inlet.

& Blower Speed are determined from the SPECIFICATION table above, use this information to select the proper pulley-belt kit from the SHEAVE SELECTION table below.

RPM

CFM RPM

RPM

CFM

CFM

AS

MODEL

BELT

AD

MODEL

BELT

OPER.

WGT.

CFM

MAX

B.H.P.

0"

0.1"

0.2"

0.3"

0.4"

0.5"

0.6"

RPM

CFM

RPM

CFM RPM CFM RPM

RPM

0.8"

CFM RPM

0.9"

CFM

RPM

1.0"

CFM RPM

0.7"

CFM

24/13.2-12
7.5-6.8/3.4

10.6-9.6/4.8

16.7-15.2/7.6

24.2-22/11

7/8
7/8

1

1/8

1

1/8

1

3/8

1
3
3
3
3

115/208-230
208-230/460
208-230/460
208-230/460
208-230/460

H.P.

VOLTS

BLOWER MOTORS

SPEED

1
1
1
1
1

49
44
83
87

121

110460-1

110464-9
110465-9
110466-9
110470-9

2
2
3
5

7

1/2

PHASE

MOTOR

AMPS*

SHAFT

DIA.

MOTOR

WGT(LB)

MOTOR

PART NO.

*Amperage shown is from National Electrical Code. Use amperage shown on motor nameplate to determine motor protector.

WATTS

73
77

GPM (5 FT. HEAD)

4.6
4.6

PUMP PART NO.

110467
110468

VOLTS

115
230

AMPS

1.0

0.58

8

325
381
381
437
493

333
390
390
446
502

316
373
373
429
485

308
364
364
420
476

D8400
D8450
D8450
D8550
D8600

B96
B96

B100
B100
B101

AS

MODEL

BELT

B90
B90
B92
B93
B95

AD

MODEL

BELT

7/8
7/8

1 1/8
1 1/8
1 3/8

MAUREY

SHEAVE

MOTOR

H.P.

BLOWER RPM/MOTOR SHEAVE 1/2 TURN DOWN

2
2
3
5

7-1/2

291
347
347
403
459

299
356
356
412
468

342
398
398
454
510

350
407
407
463
519

359
415
415
471
527

367
424
424
480
536

376
432
432
488
544

384
441
441
497
553

3DI-50
3DI-52
3DI-56
3DI-60
3DI-65

SHEAVE

BORE

CHAMPION-AD

PULLEY-BELT

KIT NO.

3DI-70
3DI-72
3DI-75
3DI-80
3DI-86

CHAMPION-AS

PULLEY-BELT

KIT NO.

* Static Pressure (inches of water). GPH = Water consumption at design conditions but does not include bleed-off amount. Amount of bleed-off will vary with different water sources, but

an amount equal to 10% of water consumption at any design condition is considered sufficient for average water. LAT = Cooler Discharge Temperature.

Pumps - 2 Required.

OUTDOOR WET-BULB

10463
12204
14735
17050

338
381
446
507

328
373
439
500

10892
12600
15082
17364

B90
B92
B93
B95

B96
B100
B100
B101

854
867
883
919

2
3
5

7

1/2

11405
13057
15480
17719

317
363
430
492

10064
11844
14410
16756

347
390
454
513

9671

11497
14106
16479

357
398
461
520

9276

11153
13810
16214

367
406
468
526

8874

10815
13520
15947

378
415
475
532

8006

10113
12948
15440

403
434
489
544

7530
9741

12659
15188

418
444
496
550

7017
9361

12361
14937

436
456
504
557

8456

10467
13234
15694

390
424
482
538

75

77
12
79
23
81
35
83
47

65

69
23
71
35
73
47
74
59

55

61
35
63
47




75

77
10
78
19
80
29
82
39

65

68
19
70
29
72
39
73
49

55

60
29
62
39




75

77

7

78
15
79
22
81
29

65

68
15
69
22
71
29
72
37

55

59
22
61
29




11902 / 0

9697 / .5

7347 / 1.0

2 H.P. MOTOR / CFM-SP*

75

77
13
79
26
81
39
83
52

65

69
26
71
39
73
52
75
66

55

61
39
63
52




75

77
11
79
23
81
34
82
46

65

69
23
71
34
72
46
74
57

55

61
34
62
46




75

77
10
79
20
80
29
82
39

65

69
20
70
29
72
39
74
49

55

60
29
62
39




13626 / 0

11669 / .5

9775 / 1.0

3 H.P. MOTOR / CFM-SP*

75

77
15
79
30
82
46
84
61

65

69
30
72
46
74
61
76
76

55

62
46
64
61




75

77
14
79
28
81
42
83
55

65

69
28
71
42
73
55
75
69

55

61
42
63
55




75

77
13
79
25
81
38
83
50

65

69
25
71
38
73
50
75
63

55

61
38
63
50




16154 / 0

14468 / .5 12915 / 1.0

5 H.P. MOTOR / CFM-SP*

75

77
17
80
34
82
51
84
68

65

70
34
72
51
74
68
77
85

55

62
51
64
68




75

77
16
80
32
82
48
84
64

65

70
32
72
48
74
64
76
79

55

62
48
64
64




75

77
15
79
30
82
44
84
59

65

69
30
72
44
74
59
76
74

55

62
44
64
59




18493 / 0

16996 / .5 15626 / 1.0

7-1/2 H.P. MOTOR / CFM-SP*

When the Cooler Model No, Motor H.P.,

This manual is related to the following products: