D 150 – Essick Air AS20012 User Manual
Page 9

AD OUTLET
E
E
A
Q
X
D
G
F
G
D
S
Q
W
R
C
J
J
N
P
B
B
A
L
M
M
E
E
N
Y
L
P
D
H
U
B
T
AD OUTLET
C
TOP VIEW
W
E
I
V
E
D
I
S
W
E
I
V
T
N
O
R
F
BLOWER
SECTION
AS OUTLET
AU OUTLET
* All measurements in inches.
D
45
45
48
1/4
48
1/4
60
1/4
H
100W
10012W
150W
15012W
20012W
WET
MODULE
NUMBER
AS/AD 100B
AS/AD 10012B
AS/AD 150B
AS/AD 15012B
AS/AD/AU 20012B
BLOWER
MODEL
NUMBER
CABINET
W
44
44
54
54
59
1/4
82
90
85
1/4
93
1/4
105
1/4
C
(AS)
13
19/32
13
19/32
16
13/16
16
13/16
18
11/16
A
DUCT
OPENING
B
21
3/4
21
3/4
26
7/8
26
7/8
31
3/4
21
3/4
21
3/4
26
7/8
26
7/8
31
3/4
U
(AD)
21
11/32
21
11/32
19
5/32
19
5/32
25
1/4
E
P
(AU)
11
5/8
11
5/8
10
11/16
10
11/16
14
1/4
N/A
N/A
N/A
N/A
24
29/32
DUCT
LOCATION
F
DRAIN
LOCATION
G
22
1/2
22
1/2
24
1/8
24
1/8
30
1/8
12
1/2
16
1/2
12
1/2
16
1/2
16
1/8
X
MEDIA
DIMENSION
Y
44
3/4
44
3/4
48
48
60
36
5/8
36
5/8
46
3/8
46
3/8
51
5/8
WET
MODULE
J
18
1/2
22
1/2
18
1/2
22
1/2
22
1/2
L
WATER
SERVICE
M
5
7/8
5
7/8
5
7/8
5
7/8
5
7/8
14
5/8
18
5/8
14
5/8
18
5/8
18
5/8
S
ELECTRIC
SERVICE
T
39
7/8
43
7/8
41
1/2
45
1/2
51
5/8
5
5/32
5
5/32
5
5/32
5
5/32
5
5/32
N
23
1/4
27
1/4
23
1/4
27
1/4
27
1/4
Q
SKID
LOCATIONS
R
4
3/4
4
3/4
4
3/4
4
3/4
4
3/4
42
42
52
52
57
1
/4
DIMENSIONAL DATA*
D 150
SIZING TABLES
SHEAVE SELECTION
MOTOR SPECIFICATIONS
SPECIFICATIONS
PERFORMANCE
Certified Air Delivery At .1" Increments Of External Static Pressure
(Inches Static Pressure Water Gauge)
2
7
9
10
12
11
6
5
4
3
1
OUTDOOR WET-BULB
LAT
GPH
LAT
GPH
LAT
GPH
LAT
GPH
85
95
105
115
OUTDOOR
DRY BULB
TEMP.
OUTDOOR WET-BULB
OUTDOOR WET-BULB
Performance shown is for installation type B - Free inlet, Ducted outlet. Power rating (BHP) does not include drive losses. Models AS/AD 150 include the affects of an 8 inch thick evaporative media on the inlet.
& Blower Speed are determined from the SPECIFICATION table above, use this information to select the proper pulley-belt kit from the SHEAVE SELECTION table below.
RPM
CFM RPM
RPM
CFM
CFM
AS
MODEL
BELT
AD
MODEL
BELT
OPER.
WGT.
CFM
MAX
B.H.P.
0"
0.1"
0.2"
0.3"
0.4"
0.5"
0.6"
RPM
CFM
RPM
CFM RPM CFM RPM
RPM
0.8"
CFM RPM
0.9"
CFM
RPM
1.0"
CFM RPM
0.7"
CFM
24/13.2-12
7.5-6.8/3.4
10.6-9.6/4.8
16.7-15.2/7.6
24.2-22/11
7/8
7/8
1
1/8
1
1/8
1
3/8
1
3
3
3
3
115/208-230
208-230/460
208-230/460
208-230/460
208-230/460
H.P.
VOLTS
BLOWER MOTORS
SPEED
1
1
1
1
1
49
44
83
87
121
110460-1
110464-9
110465-9
110466-9
110470-9
2
2
3
5
7
1/2
PHASE
MOTOR
AMPS*
SHAFT
DIA.
MOTOR
WGT(LB)
MOTOR
PART NO.
*Amperage shown is from National Electrical Code. Use amperage shown on motor nameplate to determine motor protector.
WATTS
73
77
GPM (5 FT. HEAD)
4.6
4.6
PUMP PART NO.
110467
110468
VOLTS
115
230
AMPS
1.0
0.58
8
325
381
381
437
493
333
390
390
446
502
316
373
373
429
485
308
364
364
420
476
D8400
D8450
D8450
D8550
D8600
B96
B96
B100
B100
B101
AS
MODEL
BELT
B90
B90
B92
B93
B95
AD
MODEL
BELT
7/8
7/8
1 1/8
1 1/8
1 3/8
MAUREY
SHEAVE
MOTOR
H.P.
BLOWER RPM/MOTOR SHEAVE 1/2 TURN DOWN
2
2
3
5
7-1/2
291
347
347
403
459
299
356
356
412
468
342
398
398
454
510
350
407
407
463
519
359
415
415
471
527
367
424
424
480
536
376
432
432
488
544
384
441
441
497
553
3DI-50
3DI-52
3DI-56
3DI-60
3DI-65
SHEAVE
BORE
CHAMPION-AD
PULLEY-BELT
KIT NO.
3DI-70
3DI-72
3DI-75
3DI-80
3DI-86
CHAMPION-AS
PULLEY-BELT
KIT NO.
* Static Pressure (inches of water). GPH = Water consumption at design conditions but does not include bleed-off amount. Amount of bleed-off will vary with different water sources, but
an amount equal to 10% of water consumption at any design condition is considered sufficient for average water. LAT = Cooler Discharge Temperature.
Pumps - 2 Required.
OUTDOOR WET-BULB
10463
12204
14735
17050
338
381
446
507
328
373
439
500
10892
12600
15082
17364
B90
B92
B93
B95
B96
B100
B100
B101
854
867
883
919
2
3
5
7
1/2
11405
13057
15480
17719
317
363
430
492
10064
11844
14410
16756
347
390
454
513
9671
11497
14106
16479
357
398
461
520
9276
11153
13810
16214
367
406
468
526
8874
10815
13520
15947
378
415
475
532
8006
10113
12948
15440
403
434
489
544
7530
9741
12659
15188
418
444
496
550
7017
9361
12361
14937
436
456
504
557
8456
10467
13234
15694
390
424
482
538
75
77
12
79
23
81
35
83
47
65
69
23
71
35
73
47
74
59
55
61
35
63
47
–
–
–
–
75
77
10
78
19
80
29
82
39
65
68
19
70
29
72
39
73
49
55
60
29
62
39
–
–
–
–
75
77
7
78
15
79
22
81
29
65
68
15
69
22
71
29
72
37
55
59
22
61
29
–
–
–
–
11902 / 0
9697 / .5
7347 / 1.0
2 H.P. MOTOR / CFM-SP*
75
77
13
79
26
81
39
83
52
65
69
26
71
39
73
52
75
66
55
61
39
63
52
–
–
–
–
75
77
11
79
23
81
34
82
46
65
69
23
71
34
72
46
74
57
55
61
34
62
46
–
–
–
–
75
77
10
79
20
80
29
82
39
65
69
20
70
29
72
39
74
49
55
60
29
62
39
–
–
–
–
13626 / 0
11669 / .5
9775 / 1.0
3 H.P. MOTOR / CFM-SP*
75
77
15
79
30
82
46
84
61
65
69
30
72
46
74
61
76
76
55
62
46
64
61
–
–
–
–
75
77
14
79
28
81
42
83
55
65
69
28
71
42
73
55
75
69
55
61
42
63
55
–
–
–
–
75
77
13
79
25
81
38
83
50
65
69
25
71
38
73
50
75
63
55
61
38
63
50
–
–
–
–
16154 / 0
14468 / .5 12915 / 1.0
5 H.P. MOTOR / CFM-SP*
75
77
17
80
34
82
51
84
68
65
70
34
72
51
74
68
77
85
55
62
51
64
68
–
–
–
–
75
77
16
80
32
82
48
84
64
65
70
32
72
48
74
64
76
79
55
62
48
64
64
–
–
–
–
75
77
15
79
30
82
44
84
59
65
69
30
72
44
74
59
76
74
55
62
44
64
59
–
–
–
–
18493 / 0
16996 / .5 15626 / 1.0
7-1/2 H.P. MOTOR / CFM-SP*
When the Cooler Model No, Motor H.P.,