Essick Air AS20012 User Manual
Page 11
AD OUTLET
E
E
A
Q
X
D
G
F
G
D
S
Q
W
R
C
J
J
N
P
B
B
A
L
M
M
E
E
N
Y
L
P
D
H
U
B
T
AD OUTLET
C
TOP VIEW
W
E
I
V
E
D
I
S
W
E
I
V
T
N
O
R
F
BLOWER
SECTION
AS OUTLET
AU OUTLET
* All measurements in inches.
D
45
45
48
1/4
48
1/4
60
1/4
H
100W
10012W
150W
15012W
20012W
WET
MODULE
NUMBER
AS/AD 100B
AS/AD 10012B
AS/AD 150B
AS/AD 15012B
AS/AD/AU 20012B
BLOWER
MODEL
NUMBER
CABINET
W
44
44
54
54
59
1/4
82
90
85
1/4
93
1/4
105
1/4
C
(AS)
13
19/32
13
19/32
16
13/16
16
13/16
18
11/16
A
DUCT
OPENING
B
21
3/4
21
3/4
26
7/8
26
7/8
31
3/4
21
3/4
21
3/4
26
7/8
26
7/8
31
3/4
U
(AD)
21
11/32
21
11/32
19
5/32
19
5/32
25
1/4
E
P
(AU)
11
5/8
11
5/8
10
11/16
10
11/16
14
1/4
N/A
N/A
N/A
N/A
24
29/32
DUCT
LOCATION
F
DRAIN
LOCATION
G
22
1/2
22
1/2
24
1/8
24
1/8
30
1/8
12
1/2
16
1/2
12
1/2
16
1/2
16
1/8
X
MEDIA
DIMENSION
Y
44
3/4
44
3/4
48
48
60
36
5/8
36
5/8
46
3/8
46
3/8
51
5/8
WET
MODULE
J
18
1/2
22
1/2
18
1/2
22
1/2
22
1/2
L
WATER
SERVICE
M
5
7/8
5
7/8
5
7/8
5
7/8
5
7/8
14
5/8
18
5/8
14
5/8
18
5/8
18
5/8
S
ELECTRIC
SERVICE
T
39
7/8
43
7/8
41
1/2
45
1/2
51
5/8
5
5/32
5
5/32
5
5/32
5
5/32
5
5/32
N
23
1/4
27
1/4
23
1/4
27
1/4
27
1/4
Q
SKID
LOCATIONS
R
4
3/4
4
3/4
4
3/4
4
3/4
4
3/4
42
42
52
52
57
1/4
DIMENSIONAL DATA*
SIZING TABLES
SHEAVE SELECTION
MOTOR SPECIFICATIONS
SPECIFICATIONS
PERFORMANCE
Certified Air Delivery At .1" Increments Of External Static Pressure (Inches Static Pressure Water Gauge)
2
7
9
10
12
11
6
5
4
3
1
OUTDOOR WET-BULB
LAT
GPH
LAT
GPH
LAT
GPH
LAT
GPH
85
95
105
115
OUTDOOR
DRY BULB
TEMP.
OUTDOOR WET-BULB
OUTDOOR WET-BULB
Performance shown is for installation type B - Free inlet, Ducted outlet. Power rating (BHP) does not include drive losses. Models AS/AD 15012 include the affects of a 12 inch thick evaporative media on the inlet.
determined from the SPECIFICATION table above, use this information to select the proper pulley-belt kit from the SHEAVE SELECTION table below.
RPM
CFM RPM
RPM
CFM
CFM
AS
MODEL
BELT
AD
MODEL
BELT
OPER.
WGT.
CFM
MAX
B.H.P.
0"
0.1"
0.2"
0.3"
0.4"
0.5"
0.6"
RPM
CFM
RPM
CFM RPM CFM RPM
RPM
0.8"
CFM RPM
0.9"
CFM
RPM
1.0"
CFM RPM
0.7"
CFM
24/13.2-12
7.5-6.8/3.4
10.6-9.6/4.8
16.7-15.2/7.6
24.2-22/11
7/8
7/8
1
1/8
1
1/8
1
3/8
1
3
3
3
3
115/208-230
208-230/460
208-230/460
208-230/460
208-230/460
H.P.
VOLTS
BLOWER MOTORS
SPEED
1
1
1
1
1
49
44
83
87
121
110460-1
110464-9
110465-9
110466-9
110470-9
2
2
3
5
7
1/2
PHASE
MOTOR
AMPS*
SHAFT
DIA.
MOTOR
WGT(LB)
MOTOR
PART NO.
*Amperage shown is from National Electrical Code. Use amperage shown on motor nameplate to determine motor protector.
WATTS
73
77
GPM (5 FT. HEAD)
4.6
4.6
PUMP PART NO.
110467
110468
VOLTS
115
230
AMPS
1.0
0.58
8
325
381
381
437
493
333
390
390
446
502
316
373
373
429
485
308
364
364
420
476
D8400
D8450
D8450
D8550
D8600
B96
B96
B100
B100
B101
AS
MODEL
BELT
B90
B90
B92
B93
B95
AD
MODEL
BELT
7/8
7/8
1 1/8
1 1/8
1 3/8
MAUREY
SHEAVE
MOTOR
H.P.
BLOWER RPM/MOTOR SHEAVE 1/2 TURN DOWN
2
2
3
5
7-1/2
291
347
347
403
459
299
356
356
412
468
342
398
398
454
510
350
407
407
463
519
359
415
415
471
527
367
424
424
480
536
376
432
432
488
544
384
441
441
497
553
3DI-50
3DI-52
3DI-56
3DI-60
3DI-65
SHEAVE
BORE
CHAMPION-AD
PULLEY-BELT
KIT NO.
3DI-70
3DI-72
3DI-75
3DI-80
3DI-86
CHAMPION-AS
PULLEY-BELT
KIT NO.
* Static Pressure (inches of water). GPH = Water consumption at design conditions but does not include bleed-off amount. Amount of bleed-off will vary with different water sources, but
an amount equal to 10% of water consumption at any design condition is considered sufficient for average water. LAT = Cooler Discharge Temperature.
Pumps - 2 Required.
OUTDOOR WET-BULB
10482
12225
14749
17060
324
365
427
484
314
356
419
477
10905
12604
15084
17360
B90
B92
B93
B95
B96
B100
B100
B101
967
980
996
1032
2
3
5
7-1/2
11375
13020
15438
17672
303
346
410
470
10079
11865
14434
16777
335
375
435
491
9678
11514
14133
16505
346
384
443
498
9265
11165
13838
16242
356
393
450
505
8830
10807
13540
15983
368
403
458
512
7867
10058
12899
15463
394
423
474
526
7325
9651
12640
15207
409
433
482
532
6753
9220
12328
14947
426
445
490
539
8366
10440
13246
15724
380
413
466
519
75
76
12
77
25
78
37
79
49
65
67
25
68
37
69
49
70
61
55
58
37
59
49
–
–
–
–
75
76
10
77
20
78
30
79
40
65
67
20
68
30
69
40
70
51
55
58
30
59
40
–
–
–
–
75
76
8
77
15
77
23
78
30
65
67
15
67
23
68
30
69
38
55
57
23
58
30
–
–
–
–
11375 / 0
9265 / .5
6753 / 1.0
2 H.P. MOTOR / CFM-SP*
75
76
14
77
28
78
42
79
56
65
67
28
68
42
69
56
70
70
55
58
42
59
56
–
–
–
–
75
76
12
77
24
78
36
79
48
65
67
24
68
36
69
48
70
60
55
58
36
59
48
–
–
–
–
75
76
10
77
20
78
30
79
40
65
67
20
68
30
69
40
70
50
55
58
30
59
40
–
–
–
–
13020 / 0
11165 / .5
9220 / 1.0
3 H.P. MOTOR / CFM-SP*
75
76
16
77
33
78
49
80
66
65
67
33
68
49
70
66
71
82
55
58
49
60
66
–
–
–
–
75
76
15
77
30
78
45
79
59
65
67
30
68
45
69
59
70
74
55
58
45
59
59
–
–
–
–
75
76
13
77
27
78
40
79
53
65
67
27
68
40
69
53
70
67
55
58
40
59
53
–
–
–
–
15438 / 0
13838 / .5 12328 / 1.0
5 H.P. MOTOR / CFM-SP*
75
76
17
77
33
79
50
80
67
65
67
33
69
50
70
67
71
83
55
59
50
60
67
–
–
–
–
75
76
17
77
33
79
52
80
69
65
67
35
69
52
70
69
71
87
55
59
52
60
69
–
–
–
–
75
76
16
77
32
78
48
80
64
65
67
32
68
48
70
64
71
80
55
58
48
60
64
–
–
–
–
17672 / 0
16242 / .5 14947 / 1.0
7-1/2 H.P. MOTOR / CFM-SP*
When the Cooler Model No, Motor H.P., & Blower Speed are