Essick Air AS20012 User Manual
Page 6
Q
D
E
E
A
F
G
X
D
S
Q
D
C
R
C
N
B
A
E
E
N
T
W
H
U
B
P
W
J
L
Y
M
J
SAD OUTLET
SAD OUTLET
SAS
OUTLET
TOP VIEW
W
E
I
V
E
D
I
S
W
E
I
V
T
N
O
R
F
* All measurements in inches.
D
45
45
48
1/4
48
1/4
H
100W
10012W
150W
15012W
WET
MODULE
NUMBER
SAS/SAD 100B
SAS/SAD 10012B
SAS/SAD 150B
SAS/SAD 15012B
BLOWER
MODEL
NUMBER
CABINET
W
44
44
54
54
63
3/8
67
3/8
66
5/8
70
5/8
C
(SAS)
13
19/32
13
19/32
16
13/16
16
13/16
A
DUCT
OPENING
B
21
3/4
21
3/4
26
7/8
26
7/8
21
3/4
21
3/4
26
7/8
26
7/8
U
(SAD)
21
11/32
21
11/32
19
5/32
19
5/32
E
P
(SAD)
11
5/8
11
5/8
10
11/16
10
11/16
1
29/32
1
29/32
2
7/32
2
7/32
DUCT
LOCATION
F
DRAIN
LOCATION
G
22
1/2
22
1/2
24
1/8
24
1/8
12
1/2
16
1/2
12
1/2
16
1/2
X
MEDIA
DIMENSION
Y
44
3/4
44
3/4
48
48
36
5/8
36
5/8
46
3/8
46
3/8
WET
MODULE
J
18
1/2
22
1/2
18
1/2
22
1/2
L
WATER
SERVICE
M
5
7/8
5
7/8
5
7/8
5
7/8
14
5/8
18
5/8
14
5/8
18
5/8
S
ELECTRIC
SERVICE
T
21
1/2
21
1/2
23
1/8
23
1/8
5
5/32
5
5/32
5
5/32
5
5/32
N
4
3/4
4
3/4
4
3/4
4
3/4
Q
SKID
LOCATIONS
R
4
3/4
4
3/4
4
3/4
4
3/4
42
42
52
52
DIMENSIONAL DATA*
SIZING TABLES
SHEAVE SELECTION
MOTOR SPECIFICATIONS
SPECIFICATIONS
PERFORMANCE
Certified Air Delivery At .1" Increments Of External Static Pressure
(Inches Static Pressure Water Gauge)
2
7
9
10
12
11
6
5
4
3
1
75
77
5
79
10
81
15
83
21
OUTDOOR WET-BULB
LAT
GPH
LAT
GPH
LAT
GPH
LAT
GPH
85
95
105
115
65
69
10
71
15
73
21
75
26
55
61
15
63
21
–
–
–
–
75
77
4
79
8
80
12
82
16
65
69
8
70
12
72
16
74
21
55
60
12
62
16
–
–
–
–
75
76
2
77
5
79
7
80
9
65
67
5
69
7
70
9
71
12
55
59
7
60
9
–
–
–
–
5435 / 0
4118 / .5
2197 / 1.0
OUTDOOR
DRY BULB
TEMP.
3/4 H.P. MOTOR / CFM-SP*
75
77
6
79
11
82
17
84
22
OUTDOOR WET-BULB
65
69
11
72
17
74
22
76
28
55
62
17
64
22
–
–
–
–
75
77
5
79
9
81
14
83
19
65
69
9
71
14
73
19
75
23
55
61
14
63
19
–
–
–
–
75
77
3
78
6
80
9
81
13
65
68
6
70
9
71
13
73
16
55
60
9
61
13
–
–
–
–
5983 / 0
4856 / .5
3092 / 1.0
1 H.P. MOTOR / CFM-SP*
75
77
6
80
13
82
19
84
25
OUTDOOR WET-BULB
65
70
13
72
19
74
25
77
32
55
62
19
64
25
–
–
–
–
75
77
6
79
11
81
17
84
22
65
69
11
71
17
74
22
76
28
55
61
17
64
22
–
–
–
–
75
77
4
79
9
81
13
83
18
65
69
9
71
13
73
18
75
22
55
61
13
63
18
–
–
–
–
6848 / 0
5942 / .5
4639 / 1.0
1-1/2 H.P. MOTOR / CFM-SP*
Performance shown is for installation type B - Free inlet, Ducted outlet. Power rating (BHP) does not include drive losses. Models SAS/SAD 100 include the affects of an 8 inch thick evaporative media on the inlet.
, & Blower Speed are determined from the SPECIFICATION table above, use this information to select the proper pulley-belt kit from the SHEAVE SELECTION table b elow.
RPM
CFM RPM
4863
5451
6366
376
409
463
RPM
364
398
453
CFM
5121
5684
6574
CFM
B77
B77
B77
SAS
MODEL
BELT
B83
B83
B83
SAD
MODEL
BELT
480
483
498
OPER.
WGT.
CFM
MAX
B.H.P.
0"
0.1"
0.2"
0.3"
0.4"
0.5"
0.6"
3/4
1
1
1/2
RPM
5377
5918
6774
352
388
444
CFM
RPM
4605
5215
6164
389
421
472
CFM RPM
4336
4980
5956
402
432
482
CFM RPM
4058
4734
5751
415
444
492
RPM
3754
4479
5537
430
456
502
0.8"
CFM RPM
3097
3924
5095
469
485
524
0.9"
CFM
RPM
--
3619
4859
--
503
536
1.0"
CFM RPM
--
3307
4613
--
523
548
0.7"
CFM
3429
4209
5320
448
470
513
13.8/7.6-6.9
6.9
3.5-3.2/1.6
16/8
8
4.6-4.2/2.1
5/8
5/8
5/8
5/8
5/8
7/8
1
1
3
1
1
3
115/208-230
230
208-230/460
115/230
230
208-230/460
H.P.
VOLTS
BLOWER MOTORS
SPEED
1
2
1
1
2
1
24
29
20
28
29
34
110455
110456
110461
110457
110458
110462-9
3/4
3/4
3/4
1
1
1
PHASE
MOTOR
AMPS*
SHAFT
DIA.
MOTOR
WGT(LB)
MOTOR
PART NO.
20/11-10
6.6-6/3
5/8
7/8
1
3
115/208-230
208-230/460
H.P.
VOLTS
BLOWER MOTORS
SPEED
1
1
41
40
110459-1
110463-9
1
1/2
1
1/2
PHASE
MOTOR
AMPS*
SHAFT
DIA.
MOTOR
WGT(LB)
MOTOR
PART NO.
*Amperage shown is from National Electrical Code.
Use amperage shown on motor nameplate to determine motor protector.
WATTS
73
77
GPM (5 FT. HEAD)
4.6
4.6
PUMP PART NO.
110467
110468
VOLTS
115
230
AMPS
1.0
0.58
8
343
455
343
455
353
465
353
465
333
445
333
445
323
434
323
434
8350K
8450K
8350
8450K
B83
B83
B83
B83
SAS
MODEL
BELT
B77
B77
B77
B77
SAD
MODEL
BELT
5/8*
5/8*
7/8*
7/8*
MAUREY
SHEAVE
MOTOR
H.P.
BLOWER RPM/MOTOR SHEAVE 1/2 TURN DOWN
3/4
, 1
3/4
1
1, 1
1/2
303
414
303
414
313
424
313
424
364
475
364
475
374
485
374
485
384
495
384
495
394
506
394
506
404
516
404
516
414
526
414
526
3DI-90
3DI-95
3DI-100
3DI-105
SHEAVE
BORE
CHAMPION-SAD
PULLEY-BELT
KIT NO.
3DI-110
3DI-115
3DI-120
3DI-125
CHAMPION-SAS
PULLEY-BELT
KIT NO.
*When selecting 1 H.P. motor, be sure to select Pulley-Belt Kit with same pulley bore as shaft size of motor selected.
* Static Pressure (inches of water). GPH = Water consumption at design conditions but does not include bleed-off amount. Amount of bleed-off will vary
with different water sources, but an amount equal to 10% of water consumption at any design condition is considered sufficient for average water.
Pumps - 1 Required.
When the Cooler Model No, Motor H.P.
LAT = Cooler Discharge Temperature.
,1, 1
1/2