Essick Air AS20012 User Manual

Page 13

background image

AD OUTLET

E

E

A

Q

X

D

G

F

G

D

S

Q

W

R

C

J

J

N

P

B

B

A

L

M

M

E

E

N

Y

L

P

D

H

U

B

T

AD OUTLET

C

TOP VIEW

W

E

I

V

E

D

I

S

W

E

I

V

T

N

O

R

F

BLOWER

SECTION

AS OUTLET

AU OUTLET

* All measurements in inches.

D

45
45

48

1/4

48

1/4

60

1/4

H

100W

10012W

150W

15012W
20012W

WET

MODULE

NUMBER

AS/AD 100B
AS/AD 10012B
AS/AD 150B
AS/AD 15012B
AS/AD/AU 20012B

BLOWER

MODEL

NUMBER

CABINET

W

44
44
54
54

59

1/4

82
90

85

1/4

93

1/4

105

1/4

C

(AS)

13

19/32

13

19/32

16

13/16

16

13/16

18

11/16

A

DUCT

OPENING

B

21

3/4

21

3/4

26

7/8

26

7/8

31

3/4

21

3/4

21

3/4

26

7/8

26

7/8

31

3/4

U

(AD)

21

11/32

21

11/32

19

5/32

19

5/32

25

1/4

E

P

(AU)

11

5/8

11

5/8

10

11/16

10

11/16

14

1/4

N/A
N/A
N/A
N/A

24

29/32

DUCT

LOCATION

F

DRAIN

LOCATION

G

22

1/2

22

1/2

24

1/8

24

1/8

30

1/8

12

1/2

16

1/2

12

1/2

16

1/2

16

1/8

X

MEDIA

DIMENSION

Y

44

3/4

44

3/4

48
48
60

36

5/8

36

5/8

46

3/8

46

3/8

51

5/8

WET

MODULE

J

18

1/2

22

1/2

18

1/2

22

1/2

22

1/2

L

WATER

SERVICE

M

5

7/8

5

7/8

5

7/8

5

7/8

5

7/8

14

5/8

18

5/8

14

5/8

18

5/8

18

5/8

S

ELECTRIC

SERVICE

T

39

7/8

43

7/8

41

1/2

45

1/2

51

5/8

5

5/32

5

5/32

5

5/32

5

5/32

5

5/32

N

23

1/4

27

1/4

23

1/4

27

1/4

27

1/4

Q

SKID

LOCATIONS

R

4

3/4

4

3/4

4

3/4

4

3/4

4

3/4

42
42
52
52

57

1/4

DIMENSIONAL DATA*

SIZING TABLES

SHEAVE SELECTION

MOTOR SPECIFICATIONS

SPECIFICATIONS

PERFORMANCE

Certified Air Delivery At .1" Increments Of External Static Pressure

(Inches Static Pressure Water Gauge)

2

4

1/2

5

1/2

6

7

6

1/2

4

3

1/2

3

2

1/2

OUTDOOR WET-BULB

LAT

GPH

LAT

GPH

LAT

GPH

LAT

GPH

85

95

105

115

OUTDOOR

DRY BULB

TEMP.

OUTDOOR WET-BULB

OUTDOOR WET-BULB

Performance shown is for installation type B - Free inlet, Ducted outlet. Power rating (BHP) does not include drive losses. Models AS/AD/AU 20012 include the affects of a 12 inch thick evaporative media on the inlet.

.P., & Blower Speed are determined from the SPECIFICATION table above, use this information to select the proper pulley-belt kit from the SHEAVE SELECTION table below.

RPM

AU

BELT

B92
B92
B93
B93

CFM RPM

RPM

CFM

CFM

AS

BELT

AD

BELT

OPER.

WGT.

CFM

MAX

B.H.P.

0"

0.1"

0.2"

0.3"

0.4"

0.5"

0.6"

RPM

CFM

RPM

CFM RPM CFM RPM

RPM

0.8"

CFM RPM

0.9"

CFM

RPM

1.0"

CFM RPM

0.7"

CFM

9.6/4.8

15.2/7.6

22/11
28/14

1

1/8

1

1/8

1

3/8

1

3/8

3
3
3
3

230/460
230/460
230/460
230/460

H.P.

VOLTS

BLOWER MOTORS

SPEED

1
1
1
1

83
87

121
138

110465-9
110466-9
110470-9
110482-9

3
5

7

1/2

10

PHASE

MOTOR

AMPS*

SHAFT

DIA.

MOTOR

WGT(LB)

MOTOR

PART NO.

*Amperage shown is from National Electrical Code. Use amperage shown on motor nameplate to determine motor protector.

WATTS

73
77

GPM (5 FT. HEAD)

4.6
4.6

PUMP PART NO.

110467
110468

VOLTS

115
230

AMPS

1.0

0.58

5

291
328
392
441

300
338
403
450

281
319
381
431

272
310
369
422

D8350
D8400
D8450
D8550

B92
B92
B93
B93

AU

MODEL

BELT

B112
B112
B112
B112

AS

MODEL

BELT

B100
B100
B103
B103

AD

MODEL

BELT

1 1/8
1 1/8
1 3/8
1 3/8

MAUREY

SHEAVE

MOTOR

H.P.

BLOWER RPM/TURNS OPEN OF MOTOR SHEAVE

3
5

7-1/2

10

253
291
347
403

262
300
358
412

309
347
414
459

319
356
425
469

328
365
437
478

338
375
448
488

347
384
459
497

3DI-195
3DI-200
3DI-203
3DI-205

3DI-225
3DI-230
3DI-233
3DI-235

AS

PULLEY-BELT

KIT NO.

SHEAVE

BORE

AD

PULLEY-BELT

KIT NO.

3DI-210
3DI-215
3DI-218
3DI-220

AU

PULLEY-BELT

KIT NO.

* Static Pressure (inches of water). GPH = Water consumption at design conditions but does not include bleed-off amount. Amount of bleed-off will vary with different water sources,

but an amount equal to 10% of water consumption at any design condition is considered sufficient for average water.

Pumps - 2 Required.

OUTDOOR WET-BULB

15200
18371
21270
23562

292
341
387
423

284
334
380
417

15716
18820
21670
23929

B100
B100
B103
B103

B112
B112
B112
B112

1249
1264
1297
1326

3
5

7

1/2

10

16267
19286
22077
24301

276
327
374
412

14696
17943
20888
23204

300
348
393
429

14190
17518
20514
22866

308
355
399
434

13665
17092
20142
22528

317
361
405
440

13110
16661
19769
22190

325
368
410
445

11886
15752
19015
21510

346
383
422
456

11194
15272
18629
21171

358
390
428
461

10450
14760
18229
20823

371
399
435
467

12521
16211
19395
21852

335
375
416
450

75

76
18
77
36
78
54
79
72

65

67
36
68
54
69
72
70
90

55

58
54
59
72
60
90
61

107

75

76
15
77
31
78
46
79
62

65

67
31
68
46
69
61
70
77

55

58
46
59
61
60
76
60
91

75

76
12
77
24
77
36
78
48

65

67
24
67
35
68
47
69
59

55

57
35
58
47
59
59
60
71

16267 / 0

13655 / .5 10450 / 1.0

3 H.P. MOTOR / CFM-SP*

75

76
21
77
43
78
64
79
85

65

67
42
68
64
69
85
70

106

55

58
63
59
84
60

106

61

127

75

76
19
77
38
78
57
79
76

65

67
38
68
57
69
76
70
95

55

58
56
59
75
60
94
61

113

75

76
17
77
33
78
50
79
66

65

67
33
68
49
69
66
70
82

55

58
49
59
66
60
82
61
98

19286 / 0

17092 / .5 14760 / 1.0

5 H.P. MOTOR / CFM-SP*

75

76
24
77
49
78
73
79
97

65

67
48
68
72
69
97
71

121

55

58
72
59
96
61

120

62

144

75

76
22
77
45
78
67
79
89

65

67
44
68
67
69
89
70

111

55

58
66
59
88
60

110

61

133

75

76
20
77
41
78
61
79
81

65

67
40
68
61
69
81
70

101

55

58
60
59
80
60

100

61

121

22077 / 0

20142 / .5 18229 / 1.0

7-1/2 H.P. MOTOR / CFM-SP*

75

76
27
77
53
78
80
79

107

65

67
53
68
80
69

106

71

133

55

58
79
59

106

61

132

62

159

75

76
25
77
50
78
74
79
99

65

67
49
68
74
69
99
71

123

55

58
74
59
98
61

123

62

147

75

76
23
77
46
78
69
79
92

65

67
46
68
69
69
92
70

115

55

58
68
59
91
60

114

61

137

24301 / 0

22528 / .5 20823 / 1.0

10 H.P. MOTOR / CFM-SP*

When the Cooler Model No, Motor H