Essick Air AS20012 User Manual
Page 13

AD OUTLET
E
E
A
Q
X
D
G
F
G
D
S
Q
W
R
C
J
J
N
P
B
B
A
L
M
M
E
E
N
Y
L
P
D
H
U
B
T
AD OUTLET
C
TOP VIEW
W
E
I
V
E
D
I
S
W
E
I
V
T
N
O
R
F
BLOWER
SECTION
AS OUTLET
AU OUTLET
* All measurements in inches.
D
45
45
48
1/4
48
1/4
60
1/4
H
100W
10012W
150W
15012W
20012W
WET
MODULE
NUMBER
AS/AD 100B
AS/AD 10012B
AS/AD 150B
AS/AD 15012B
AS/AD/AU 20012B
BLOWER
MODEL
NUMBER
CABINET
W
44
44
54
54
59
1/4
82
90
85
1/4
93
1/4
105
1/4
C
(AS)
13
19/32
13
19/32
16
13/16
16
13/16
18
11/16
A
DUCT
OPENING
B
21
3/4
21
3/4
26
7/8
26
7/8
31
3/4
21
3/4
21
3/4
26
7/8
26
7/8
31
3/4
U
(AD)
21
11/32
21
11/32
19
5/32
19
5/32
25
1/4
E
P
(AU)
11
5/8
11
5/8
10
11/16
10
11/16
14
1/4
N/A
N/A
N/A
N/A
24
29/32
DUCT
LOCATION
F
DRAIN
LOCATION
G
22
1/2
22
1/2
24
1/8
24
1/8
30
1/8
12
1/2
16
1/2
12
1/2
16
1/2
16
1/8
X
MEDIA
DIMENSION
Y
44
3/4
44
3/4
48
48
60
36
5/8
36
5/8
46
3/8
46
3/8
51
5/8
WET
MODULE
J
18
1/2
22
1/2
18
1/2
22
1/2
22
1/2
L
WATER
SERVICE
M
5
7/8
5
7/8
5
7/8
5
7/8
5
7/8
14
5/8
18
5/8
14
5/8
18
5/8
18
5/8
S
ELECTRIC
SERVICE
T
39
7/8
43
7/8
41
1/2
45
1/2
51
5/8
5
5/32
5
5/32
5
5/32
5
5/32
5
5/32
N
23
1/4
27
1/4
23
1/4
27
1/4
27
1/4
Q
SKID
LOCATIONS
R
4
3/4
4
3/4
4
3/4
4
3/4
4
3/4
42
42
52
52
57
1/4
DIMENSIONAL DATA*
SIZING TABLES
SHEAVE SELECTION
MOTOR SPECIFICATIONS
SPECIFICATIONS
PERFORMANCE
Certified Air Delivery At .1" Increments Of External Static Pressure
(Inches Static Pressure Water Gauge)
2
4
1/2
5
1/2
6
7
6
1/2
4
3
1/2
3
2
1/2
OUTDOOR WET-BULB
LAT
GPH
LAT
GPH
LAT
GPH
LAT
GPH
85
95
105
115
OUTDOOR
DRY BULB
TEMP.
OUTDOOR WET-BULB
OUTDOOR WET-BULB
Performance shown is for installation type B - Free inlet, Ducted outlet. Power rating (BHP) does not include drive losses. Models AS/AD/AU 20012 include the affects of a 12 inch thick evaporative media on the inlet.
.P., & Blower Speed are determined from the SPECIFICATION table above, use this information to select the proper pulley-belt kit from the SHEAVE SELECTION table below.
RPM
AU
BELT
B92
B92
B93
B93
CFM RPM
RPM
CFM
CFM
AS
BELT
AD
BELT
OPER.
WGT.
CFM
MAX
B.H.P.
0"
0.1"
0.2"
0.3"
0.4"
0.5"
0.6"
RPM
CFM
RPM
CFM RPM CFM RPM
RPM
0.8"
CFM RPM
0.9"
CFM
RPM
1.0"
CFM RPM
0.7"
CFM
9.6/4.8
15.2/7.6
22/11
28/14
1
1/8
1
1/8
1
3/8
1
3/8
3
3
3
3
230/460
230/460
230/460
230/460
H.P.
VOLTS
BLOWER MOTORS
SPEED
1
1
1
1
83
87
121
138
110465-9
110466-9
110470-9
110482-9
3
5
7
1/2
10
PHASE
MOTOR
AMPS*
SHAFT
DIA.
MOTOR
WGT(LB)
MOTOR
PART NO.
*Amperage shown is from National Electrical Code. Use amperage shown on motor nameplate to determine motor protector.
WATTS
73
77
GPM (5 FT. HEAD)
4.6
4.6
PUMP PART NO.
110467
110468
VOLTS
115
230
AMPS
1.0
0.58
5
291
328
392
441
300
338
403
450
281
319
381
431
272
310
369
422
D8350
D8400
D8450
D8550
B92
B92
B93
B93
AU
MODEL
BELT
B112
B112
B112
B112
AS
MODEL
BELT
B100
B100
B103
B103
AD
MODEL
BELT
1 1/8
1 1/8
1 3/8
1 3/8
MAUREY
SHEAVE
MOTOR
H.P.
BLOWER RPM/TURNS OPEN OF MOTOR SHEAVE
3
5
7-1/2
10
253
291
347
403
262
300
358
412
309
347
414
459
319
356
425
469
328
365
437
478
338
375
448
488
347
384
459
497
3DI-195
3DI-200
3DI-203
3DI-205
3DI-225
3DI-230
3DI-233
3DI-235
AS
PULLEY-BELT
KIT NO.
SHEAVE
BORE
AD
PULLEY-BELT
KIT NO.
3DI-210
3DI-215
3DI-218
3DI-220
AU
PULLEY-BELT
KIT NO.
* Static Pressure (inches of water). GPH = Water consumption at design conditions but does not include bleed-off amount. Amount of bleed-off will vary with different water sources,
but an amount equal to 10% of water consumption at any design condition is considered sufficient for average water.
Pumps - 2 Required.
OUTDOOR WET-BULB
15200
18371
21270
23562
292
341
387
423
284
334
380
417
15716
18820
21670
23929
B100
B100
B103
B103
B112
B112
B112
B112
1249
1264
1297
1326
3
5
7
1/2
10
16267
19286
22077
24301
276
327
374
412
14696
17943
20888
23204
300
348
393
429
14190
17518
20514
22866
308
355
399
434
13665
17092
20142
22528
317
361
405
440
13110
16661
19769
22190
325
368
410
445
11886
15752
19015
21510
346
383
422
456
11194
15272
18629
21171
358
390
428
461
10450
14760
18229
20823
371
399
435
467
12521
16211
19395
21852
335
375
416
450
75
76
18
77
36
78
54
79
72
65
67
36
68
54
69
72
70
90
55
58
54
59
72
60
90
61
107
75
76
15
77
31
78
46
79
62
65
67
31
68
46
69
61
70
77
55
58
46
59
61
60
76
60
91
75
76
12
77
24
77
36
78
48
65
67
24
67
35
68
47
69
59
55
57
35
58
47
59
59
60
71
16267 / 0
13655 / .5 10450 / 1.0
3 H.P. MOTOR / CFM-SP*
75
76
21
77
43
78
64
79
85
65
67
42
68
64
69
85
70
106
55
58
63
59
84
60
106
61
127
75
76
19
77
38
78
57
79
76
65
67
38
68
57
69
76
70
95
55
58
56
59
75
60
94
61
113
75
76
17
77
33
78
50
79
66
65
67
33
68
49
69
66
70
82
55
58
49
59
66
60
82
61
98
19286 / 0
17092 / .5 14760 / 1.0
5 H.P. MOTOR / CFM-SP*
75
76
24
77
49
78
73
79
97
65
67
48
68
72
69
97
71
121
55
58
72
59
96
61
120
62
144
75
76
22
77
45
78
67
79
89
65
67
44
68
67
69
89
70
111
55
58
66
59
88
60
110
61
133
75
76
20
77
41
78
61
79
81
65
67
40
68
61
69
81
70
101
55
58
60
59
80
60
100
61
121
22077 / 0
20142 / .5 18229 / 1.0
7-1/2 H.P. MOTOR / CFM-SP*
75
76
27
77
53
78
80
79
107
65
67
53
68
80
69
106
71
133
55
58
79
59
106
61
132
62
159
75
76
25
77
50
78
74
79
99
65
67
49
68
74
69
99
71
123
55
58
74
59
98
61
123
62
147
75
76
23
77
46
78
69
79
92
65
67
46
68
69
69
92
70
115
55
58
68
59
91
60
114
61
137
24301 / 0
22528 / .5 20823 / 1.0
10 H.P. MOTOR / CFM-SP*
When the Cooler Model No, Motor H