beautypg.com

Essick Air AS20012 User Manual

Page 8

background image

Q

D

E

E

A

F

G

X

D

S

Q

D

C

R

C

N

B

A

E

E

N

T

W

H

U

B

P

W

J

L

Y

M

J

SAD OUTLET

SAD OUTLET

SAS

OUTLET

TOP VIEW

W

E

I

V

E

D

I

S

W

E

I

V

T

N

O

R

F

* All measurements in inches.

D

45
45

48

1/4

48

1/4

H

100W

10012W

150W

15012W

WET

MODULE

NUMBER

SAS/SAD 100B
SAS/SAD 10012B
SAS/SAD 150B
SAS/SAD 15012B

BLOWER

MODEL

NUMBER

CABINET

W

44
44
54
54

63

3/8

67

3/8

66

5/8

70

5/8

C

(SAS)

13

19/32

13

19/32

16

13/16

16

13/16

A

DUCT

OPENING

B

21

3/4

21

3/4

26

7/8

26

7/8

21

3/4

21

3/4

26

7/8

26

7/8

U

(SAD)

21

11/32

21

11/32

19

5/32

19

5/32

E

P

(SAD)

11

5/8

11

5/8

10

11/16

10

11/16

1

29/32

1

29/32

2

7/32

2

7/32

DUCT

LOCATION

F

DRAIN

LOCATION

G

22

1/2

22

1/2

24

1/8

24

1/8

12

1/2

16

1/2

12

1/2

16

1/2

X

MEDIA

DIMENSION

Y

44

3/4

44

3/4

48
48

36

5/8

36

5/8

46

3/8

46

3/8

WET

MODULE

J

18

1/2

22

1/2

18

1/2

22

1/2

L

WATER

SERVICE

M

5

7/8

5

7/8

5

7/8

5

7/8

14

5/8

18

5/8

14

5/8

18

5/8

S

ELECTRIC

SERVICE

T

21

1/2

21

1/2

23

1/8

23

1/8

5

5/32

5

5/32

5

5/32

5

5/32

N

4

3/4

4

3/4

4

3/4

4

3/4

Q

SKID

LOCATIONS

R

4

3/4

4

3/4

4

3/4

4

3/4

42
42
52
52

DIMENSIONAL DATA*

AD 10012

SIZING TABLES

SHEAVE SELECTION

MOTOR SPECIFICATIONS

SPECIFICATIONS

PERFORMANCE

Certified Air Delivery At .1" Increments Of External Static Pressure (Inches Static Pressure Water Gauge)

2

7

9

10

12

11

6

5

4

3

1

OUTDOOR WET-BULB

LAT

GPH

LAT

GPH

LAT

GPH

LAT

GPH

85

95

105

115

OUTDOOR

DRY BULB

TEMP.

OUTDOOR WET-BULB

OUTDOOR WET-BULB

RPM

CFM RPM

RPM

CFM

CFM

SAS

MODEL

BELT

SAD

MODEL

BELT

OPER.

WGT.

CFM

MAX

B.H.P.

0"

0.1"

0.2"

0.3"

0.4"

0.5"

0.6"

RPM

CFM

RPM

CFM RPM CFM RPM

RPM

0.8"

CFM RPM

0.9"

CFM

RPM

1.0"

CFM RPM

0.7"

CFM

13.8/7.6-6.9

6.9

3.5-3.2/1.6

16/8

8

4.6-4.2/2.1

5/8
5/8
5/8
5/8
5/8
7/8

1
1
3
1
1
3

115/208-230

230

208-230/460

115/230

230

208-230/460

H.P.

VOLTS

BLOWER MOTORS

SPEED

1
2
1
1
2
1

24
29
20
28
29
34

110455
110456
110461
110457
110458

110462-9

3/4
3/4
3/4

1
1
1

PHASE

MOTOR

AMPS*

SHAFT

DIA.

MOTOR

WGT(LB)

MOTOR

PART NO.

20/11-10

6.6-6/3

5/8
7/8

1
3

115/208-230
208-230/460

H.P.

VOLTS

BLOWER MOTORS

SPEED

1
1

41
40

110459-1

110463-9

1

1/2

1

1/2

PHASE

MOTOR

AMPS*

SHAFT

DIA.

MOTOR

WGT(LB)

MOTOR

PART NO.

*Amperage shown is from National Electrical Code.

WATTS

73
77

GPM (5 FT. HEAD)

4.6
4.6

PUMP PART NO.

110467
110468

VOLTS

115
230

AMPS

1.0

0.58

8

343
455
343
455

353
465
353
465

333
445
333
445

323
434
323
434

8350K
8450K

8350

8450K

B83
B83
B83
B83

SAS

MODEL

BELT

B77
B77
B77
B77

SAD

MODEL

BELT

5/8*
5/8*
7/8*
7/8*

MAUREY

SHEAVE

MOTOR

H.P.

BLOWER RPM/MOTOR SHEAVE 1/2 TURN DOWN

3/4

, 1

3/4

, 1,

1

1, 1

1/2

303
414
303
414

313
424
313
424

364
475
364
475

374
485
374
485

384
495
384
495

394
506
394
506

404
516
404
516

414
526
414
526

3DI-90
3DI-95

3DI-100
3DI-105

SHEAVE

BORE

CHAMPION-SAD

PULLEY-BELT

KIT NO.

3DI-110
3DI-115
3DI-120
3DI-125

CHAMPION-SAS

PULLEY-BELT

KIT NO.

*When selecting 1 H.P. motor, be sure to select Pulley-Belt Kit with same pulley bore as shaft size of motor selected.

* Static Pressure (inches of water). GPH = Water consumption at design conditions but does not include bleed-off amount. Amount of bleed-off will

an amount equal to 10% of water consumption at any design condition is considered sufficient for average water.

LAT = Cooler Discharge Temperature.

Pumps - 1 Required.

4794
5375
6286

386
420
475

374
410
466

5064
5627
6513

B77
B77
B77

B83
B83
B83

527
530
545

3/4

1

1

1/2

5371
5911
6767

362
359
457

4536
5142
6076

397
431
484

4269
4907
5872

410
441
494

3985
4663
5666

423
453
503

3667
4399
5456

439
465
513

2952
3809
5008

481
495
534

2591
3480
4755

507
514
546

2261
3145
4497

534
536
560

3318
4115
5238

458
479
523

75

76

6

77
12
78
17
79
23

65

67
12
68
17
69
23
70
29

55

58
17
59
23




75

76

6

77
12
78
12
79
16

65

67
12
68
17
69
16
70
20

55

58
13
59
23




75

76

2

76

5

77

7

78

9

65

66

5

67

7

68

9

68
11

55

57

7

58

9



5377 / 0

4007 / .5

2120 / 1.0

75

76

6

77
13
78
19
79
25

65

67
13
68
19
69
25
71
32

55

58
19
59
25




75

76

6

77
10
78
15
79
20

65

67
13
68
15
69
20
70
25

55

58
19
59
20




75

76

5

77

7

78
10
78
13

65

67
10
68
10
68
13
69
16

55

58
16
58
13




5917 / 0

4712 / .5

2970 / 1.0

1 H.P. MOTOR / CFM-SP*

75

76

7

77
14
79
22
80
29

65

67
14
69
22
70
29
71
36

55

59
22
60
29




75

76

6

77
12
78
18
80
25

65

67
12
68
18
70
25
71
31

55

58
18
60
25




75

76

5

77
10
78
15
79
19

65

67
10
68
15
69
19
70
24

55

58
15
59
19




6761 / 0

5761 / .5

4447 / 1.0

1-1/2 H.P. MOTOR / CFM-SP*

3/4 H.P. MOTOR / CFM-SP*

Performance shown is for installation type B - Free inlet, Ducted outlet. Power rating (BHP) does not include drive losses. Models SAS/SAD 10012 include the affects of a 12 inch thick evaporative media on the inlet.

& Blower Speed are determined from the SPECIFICATION table above, use this information to select the proper pulley-belt kit from the SHEAVE SELECTION table below.

When the Cooler Model No, Motor H.P.

Use amperage shown on motor nameplate to determine motor protector.

vary with different water sources, but

1

1/2

This manual is related to the following products: