beautypg.com

Essick Air AS20012 User Manual

Page 7

background image

AD OUTLET

E

E

A

Q

X

D

G

F

G

D

S

Q

W

R

C

J

J

N

P

B

B

A

L

M

M

E

E

N

Y

L

P

D

H

U

B

T

AD OUTLET

C

TOP VIEW

W

E

I

V

E

D

I

S

W

E

I

V

T

N

O

R

F

BLOWER

SECTION

AS OUTLET

AU OUTLET

* All measurements in inches.

D

45
45

48

1/4

48

1/4

60

1/4

H

100W

10012W

150W

15012W
20012W

WET

MODULE
NUMBER

AS/AD 100B
AS/AD 10012B
AS/AD 150B
AS/AD 15012B
AS/AD/AU 20012B

BLOWER

MODEL

NUMBER

CABINET

W

44
44
54
54

59

1/4

82
90

85

1/4

93

1/4

105

1/4

C

(AS)

13

19/32

13

19/32

16

13/16

16

13/16

18

11/16

A

DUCT

OPENING

B

21

3/4

21

3/4

26

7/8

26

7/8

31

3/4

21

3/4

21

3/4

26

7/8

26

7/8

31

3/4

U

(AD)

21

11/32

21

11/32

19

5/32

19

5/32

25

1/4

E

P

(AU)

11

5/8

11

5/8

10

11/16

10

11/16

14

1/4

N/A
N/A
N/A
N/A

24

29/32

DUCT

LOCATION

F

DRAIN

LOCATION

G

22

1/2

22

1/2

24

1/8

24

1/8

30

1/8

12

1/2

16

1/2

12

1/2

16

1/2

16

1/8

X

MEDIA

DIMENSION

Y

44

3/4

44

3/4

48
48
60

36

5/8

36

5/8

46

3/8

46

3/8

51

5/8

WET

MODULE

J

18

1/2

22

1/2

18

1/2

22

1/2

22

1/2

L

WATER

SERVICE

M

5

7/8

5

7/8

5

7/8

5

7/8

5

7/8

14

5/8

18

5/8

14

5/8

18

5/8

18

5/8

S

ELECTRIC

SERVICE

T

39

7/8

43

7/8

41

1/2

45

1/2

51

5/8

5

5/32

5

5/32

5

5/32

5

5/32

5

5/32

N

23

1/4

27

1/4

23

1/4

27

1/4

27

1/4

Q

SKID

LOCATIONS

R

4

3/4

4

3/4

4

3/4

4

3/4

4

3/4

42
42
52
52

57

1/4

DIMENSIONAL DATA*

SIZING TABLES

SHEAVE SELECTION

MOTOR SPECIFICATIONS

SPECIFICATIONS

PERFORMANCE

Certified Air Delivery At .1" Increments Of External Static Pressure

(Inches Static Pressure Water Gauge)

2

7

9

10

12

11

6

5

4

3

1

OUTDOOR WET-BULB

LAT

GPH

LAT

GPH

LAT

GPH

LAT

GPH

85

95

105

115

OUTDOOR

DRY BULB

TEMP.

OUTDOOR WET-BULB

OUTDOOR WET-BULB

Performance shown is for installation type B - Free inlet, Ducted outlet. Power rating (BHP) does not include drive losses. Models AS/AD 10012 include the affects of a 12 inch thick evaporative media on the inlet.

, & Blower Speed are determined from the SPECIFICATION table above, use this information to select the proper pulley-belt kit from the SHEAVE SELECTION table below.

RPM

CFM RPM

RPM

CFM

CFM

AS

MODEL

BELT

AD

MODEL

BELT

OPER.

WGT.

CFM

MAX

B.H.P.

0"

0.1"

0.2"

0.3"

0.4"

0.5"

0.6"

RPM

CFM

RPM

CFM RPM CFM RPM

RPM

0.8"

CFM RPM

0.9"

CFM

RPM

1.0"

CFM RPM

0.7"

CFM

20/11-10

6.6-6/3

24/13.2-12
7.5-6.8/3.4

10.6-9.6/4.8

16.7-15.2/7.6

5/8
7/8
7/8
7/8

1

1/8

1

1/8

1
3
1
3
3
3

115/208-230
208-230/460
115/208-230
208-230/460
208-230/460
208-230/460

H.P.

VOLTS

BLOWER MOTORS

SPEED

1
1
1
1
1
1

41
40
49
44
83
87

110459-1

110463-9

110460-1

110464-9
110465-9
110466-9

1

1/2

1

1/2

2
2
3
5

PHASE

MOTOR

AMPS*

SHAFT

DIA.

MOTOR

WGT(LB)

MOTOR

PART NO.

*Amperage shown is from National Electrical Code. Use amperage shown on motor nameplate to determine motor protector.

WATTS

73
77

GPM (5 FT. HEAD)

4.6
4.6

PUMP PART NO.

110467
110468

VOLTS

115
230

AMPS

1.0

0.58

8

433
455
523
590

443
465
533
600

422
445
513
580

412
434
502
569

D8450
D8450
D8550
D8600

A82
B83
B86
B87

AS

MODEL

BELT

A76
B77
B80
B81

AD

MODEL

BELT

7/8
7/8

1 1/8
1 1/8

MAUREY

SHEAVE

MOTOR

H.P.

BLOWER RPM/MOTOR SHEAVE 1/2 TURN DOWN

1-1/2

2
3
5

391
414
482
549

401
424
492
559

454
475
543
610

464
485
553
620

475
495
563
630

485
506
574
641

496
516
584
651

506
526
594
661

3DI-10
3DI-15
3DI-20
3DI-25

SHEAVE

BORE

CHAMPION-AD

PULLEY-BELT

KIT NO.

3DI-30
3DI-35
3DI-40
3DI-45

CHAMPION-AS

PULLEY-BELT

KIT NO.

* Static Pressure (inches of water). GPH = Water consumption at design conditions but does not include bleed-off amount. Amount of bleed-off will vary with different water sources, but

an amount equal to 10% of water consumption at any design condition is considered sufficient for average water. LAT = Cooler Discharge Temperature.

Pumps - 2 Required.

OUTDOOR WET-BULB

7052
7842
9075

10868

400
436
494
581

390
427
487
575

7255
8024
9235

11001

A76
B77
B80
B81

A82
B83
B86
B87

801
805
818
834

1

1/2

2
3
5

7431
8178
9362

11099

382
421
482
571

6835
7649
8914

10736

411
446
502
587

6611
7450
8744

10598

424
457
511
594

6376
7244
8572

10457

437
468
520
601

6131
7030
8393

10313

450
480
531
609

5610
6580
8024

10016

477
504
551
625

5327
6343
7827
9862

492
517
562
634

5031
6095
7631
9709

507
529
672
643

5877
6809
8209

10165

464
492
541
617

75

76

8

77
17
78
25
79
34

65

67
17
68
25
69
34
70
42

55

58
25
59
34




75

76

7

77
14
78
21
79
28

65

67
14
68
21
69
28
70
35

55

58
21
59
28




75

76

6

77
11
77
17
78
22

65

67
11
67
17
68
22
69
28

55

57
17
58
22




7431 / 0

6376 / .5

5031 / 1.0

1-1/2 H.P. MOTOR / CFM-SP*

75

76

9

77
18
78
28
79
37

65

67
18
68
28
69
37
70
46

55

58
28
59
37




75

76

8

77
16
78
24
79
32

65

67
16
68
24
69
32
70
40

55

58
24
59
32




75

76

7

77
13
78
20
79
27

65

67
13
68
20
69
27
69
33

55

58
20
59
27



8178 / 0

7244 / .5

6095 / 1.0

2 H.P. MOTOR / CFM-SP*

75

76
11
77
21
78
32
79
42

65

67
21
68
32
69
42
70
53

55

58
32
59
42




75

76

9

77
19
78
28
79
38

65

67
19
68
28
69
38
70
47

55

58
28
59
38




75

76

8

77
17
78
25
79
33

65

67
17
68
25
69
33
70
42

55

58
25
59
32




9362 / 0

8572 / .5

7631 / 1.0

3 H.P. MOTOR / CFM-SP*

75

76
12
77
25
78
37
80
49

65

67
25
68
37
70
49
71
62

55

58
37
60
49




75

76
11
77
23
78
34
79
46

65

67
23
68
34
69
46
71
57

55

58
34
59
46




75

76
11
77
21
78
32
79
42

65

67
21
68
32
69
42
70
53

55

58
32
59
42




11099 / 0

10457 / .5 9709 / 1.0

5 H.P. MOTOR / CFM-SP*

When the Cooler Model No, Motor H.P.

433

443

422

412

D8450

A82

A76

5/8

1-1/2

391

401

454

464

475

485

496

506

3DI-11

3DI-31

This manual is related to the following products: