beautypg.com

Essick Air AS20012 User Manual

Page 12

background image

Q

D

E

E

A

F

G

X

D

S

Q

D

C

R

C

N

B

A

E

E

N

T

W

H

U

B

P

W

J

L

Y

M

J

SAD OUTLET

SAD OUTLET

SAS

OUTLET

TOP VIEW

W

E

I

V

E

D

I

S

W

E

I

V

T

N

O

R

F

* All measurements in inches.

D

45
45

48

1/4

48

1/4

H

100W

10012W

150W

15012W

WET

MODULE

NUMBER

SAS/SAD 100B
SAS/SAD 10012B
SAS/SAD 150B
SAS/SAD 15012B

BLOWER

MODEL

NUMBER

CABINET

W

44
44
54
54

63

3/8

67

3/8

66

5/8

70

5/8

C

(SAS)

13

19/32

13

19/32

16

13/16

16

13/16

A

DUCT

OPENING

B

21

3/4

21

3/4

26

7/8

26

7/8

21

3/4

21

3/4

26

7/8

26

7/8

U

(SAD)

21

11/32

21

11/32

19

5/32

19

5/32

E

P

(SAD)

11

5/8

11

5/8

10

11/16

10

11/16

1

29/32

1

29/32

2

7/32

2

7/32

DUCT

LOCATION

F

DRAIN

LOCATION

G

22

1/2

22

1/2

24

1/8

24

1/8

12

1/2

16

1/2

12

1/2

16

1/2

X

MEDIA

DIMENSION

Y

44

3/4

44

3/4

48
48

36

5/8

36

5/8

46

3/8

46

3/8

WET

MODULE

J

18

1/2

22

1/2

18

1/2

22

1/2

L

WATER

SERVICE

M

5

7/8

5

7/8

5

7/8

5

7/8

14

5/8

18

5/8

14

5/8

18

5/8

S

ELECTRIC

SERVICE

T

21

1/2

21

1/2

23

1/8

23

1/8

5

5/32

5

5/32

5

5/32

5

5/32

N

4

3/4

4

3/4

4

3/4

4

3/4

Q

SKID

LOCATIONS

R

4

3/4

4

3/4

4

3/4

4

3/4

42
42
52
52

DIMENSIONAL DATA*

SIZING TABLES

SHEAVE SELECTION

MOTOR SPECIFICATIONS

SPECIFICATIONS

PERFORMANCE

Certified Air Delivery At .1" Increments Of External Static Pressure (Inches Static Pressure Water Gauge)

2

7

9

10

12

11

6

5

4

3

1

OUTDOOR WET-BULB

LAT

GPH

LAT

GPH

LAT

GPH

LAT

GPH

85

95

105

115

OUTDOOR

DRY BULB

TEMP.

OUTDOOR WET-BULB

OUTDOOR WET-BULB

Performance shown is for installation type B - Free inlet, Ducted outlet. Power rating (BHP) does not include drive losses. Models SAS/SAD 15012 include the affects of a 12 inch thick evaporative media on the inlet.

., & Blower Speed are determined from the SPECIFICATION table above, use this information to select the proper pulley-belt kit from the SHEAVE SELECTION table below.

RPM

CFM RPM

RPM

CFM

CFM

SAS

MODEL

BELT

SAD

MODEL

BELT

OPER.

WGT.

CFM

MAX

B.H.P.

0"

0.1"

0.2"

0.3"

0.4"

0.5"

0.6"

RPM

CFM

RPM

CFM RPM CFM RPM

RPM

0.8"

CFM RPM

0.9"

CFM

RPM

1.0"

CFM RPM

0.7"

CFM

13.8/7.6-6.9

6.9

3.5-3.2/1.6

16/8

8

4.6-4.2/2.1

20/11-10

6.6-6/3

5/8
5/8
5/8
5/8
5/8
7/8
5/8
7/8

1
1
3
1
1
3
1
3

115/208-230

230

208-230/460

115/230

230

208-230/460
115/208-230
208-230/460

H.P.

VOLTS

BLOWER MOTORS

SPEED

1
2
1
1
2
1
1
1

24
29
20
28
29
34
41
40

110455
110456
110461
110457
110458

110462-9

110459-1

110463-9

3/4
3/4
3/4

1
1
1

1

1/2

1

1/2

PHASE

MOTOR

AMPS*

SHAFT

DIA.

MOTOR

WGT(LB)

MOTOR

PART NO.

24/13.2-12
7.5-6.8/3.4

10.6-9.6/4.8

7/8
7/8

1

1/8

1
3
3

115/208-230
208-230/460
208-230/460

H.P.

VOLTS

BLOWER MOTORS

SPEED

1
1
1

49
44
83

110460-1

110464-9
110465-9

2
2
3

PHASE

MOTOR

AMPS*

SHAFT

DIA.

MOTOR

WGT(LB)

MOTOR

PART NO.

*Amperage shown is from National Electrical Code. Use amperage shown on motor nameplate to determine motor protector.

WATTS

73
77

GPM (5 FT. HEAD)

4.6
4.6

PUMP PART NO.

110467
110468

VOLTS

115
230

AMPS

1.0

0.58

8

287
381
287
381
437
437

296
390
296
390
446
446

278
373
278
373
429
429

269
364
269
364
420
420

8350K
8450K

8350

8450K

8550
8550

B96
B96
B96
B96
B96

B100

SAS

MODEL

BELT

B90
B90
B90
B90
B90
B92

SAD

MODEL

BELT

5/8*
5/8*
7/8*
7/8*

7/8

1 1/8

MAUREY

SHEAVE

MOTOR

H.P.

BLOWER RPM/MOTOR SHEAVE 1/2 TURN DOWN

3/4

, 1

1

1, 1

1/2

, 2

1

1/2

, 2

3

253
347
253
347
403
403

261
356
261
356
412
412

304
398
304
398
454
454

313
407
313
407
463
463

321
415
321
415
471
471

330
424
330
424
480
480

338
432
338
432
488
488

347
441
347
441
497
497

3DI-130
3DI-135
3DI-140
3DI-145
3DI-155
3DI-161

SHEAVE

BORE

CHAMPION-SAD

PULLEY-BELT

KIT NO.

3DI-165
3DI-170
3DI-175
3DI-180
3DI-185
3DI-190

CHAMPION-SAS

PULLEY-BELT

KIT NO.

*When selecting 1 H.P. motor, be sure to select Pulley-Belt Kit with same pulley bore as shaft size of motor selected.

* Static Pressure (inches of water). GPH = Water consumption at design conditions but does not include bleed-off amount. Amount of bleed-off will vary with different water sources, but

an amount equal to 10% of water consumption at any design condition is considered sufficient for average water. LAT = Cooler Discharge Temperature.

Pumps - 1 Required.

OUTDOOR WET-BULB

OUTDOOR WET-BULB

6087
6876
8091
9044

N/A

289
314
353
386

N/A

278
303
345
378

N/A

6539
7286
8455
9375

N/A

B90
B90
B90
B90
B92

B96
B96
B96
B96

B100

645
649
665
669
681

3/4

1

1

1/2

2
3

6997
7702
8817

N/A
N/A

267
294
336

N/A
N/A

5603
6450
7734
8719

N/A

301
324
363
394

N/A

5051
5994
7359
8389

N/A

315
336
372
402

N/A

4415
5477
6961
8043

N/A

332
349
382
411

N/A

3717
4893
6525
7683
9377

353
364
393
420
466

2497
3637
5527
6869
8751

398
404
419
440
482

2013
3085
4976
6416
8407

419
425
435
452
490

1571
2609
4425
5932
8046

436
444
453
465
499

3058
4260
6050
7293
9070

376
383
405
430
474

75

76

8

77
15
78
23
79
30

65

67
15
68
23
69
30
70
38

55

58
23
59
30




75

76

4

77
10
78
14
79
19

65

67

9

68
14
69
19
70
24

55

58
13
59
19




75

76

2

76

4

76

5

76

7

65

66

4

66

5

66

7

67

9

55

56

5

56

7



6997 / 0

4415 / .5

1571 / 1.0

3/4 H.P. MOTOR / CFM-SP*

75

76

8

77
16
78
25
80
33

65

67
16
68
25
70
33
71
41

55

58
25
60
33




75

76

6

77
12
78
18
79
24

65

67
12
68
18
69
24
70
30

55

58
18
59
24




75

76

3

76

6

78

9

78
12

65

66

6

67

9

68
12
68
15

55

57

9

58
12




7702 / 0

5477 / .5

2609 / 1.0

1 H.P. MOTOR / CFM-SP*

75

76

9

77
19
79
28
80
37

65

67
19
69
28
70
37
71
47

55

59
28
60
37




75

76

7

77
15
78
22
79
30

65

67
15
68
22
69
30
70
37

55

58
22
59
30




75

76

5

77
10
78
15
79
19

65

67
10
68
15
69
19
70
24

55

58
15
59
19




8817 / 0

6961 / .5

4425 / 1.0

1-1/2 H.P. MOTOR / CFM-SP*

75

76
10
77
20
79
30
80
41

65

67
20
69
30
70
41
71
51

55

59
30
60
41




75

76

9

77
17
78
26
80
34

65

67
17
68
26
70
34
71
43

55

58
26
60
34




75

76

6

77
13
78
19
79
26

65

67
13
68
19
69
26
70
32

55

58
19
59
26




9375 / .1

8043 / .5

5932 / 1.0

2 H.P. MOTOR / CFM-SP*

75








65








55








75

76
10
77
20
79
30
80
41

65

67
20
69
30
70
41
71
51

55

59
30
60
41




75

76

9

77
17
78
26
80
34

65

67
17
68
26
70
34
71
43

55

58
26
60
34




9377 / .6

8046 / 1.0

3 H.P. MOTOR / CFM-SP*

When the Cooler Model No, Motor H.P

, 1

1/2

3/4

,1

This manual is related to the following products: