Able index, How to use this index – Essick Air AS20012 User Manual
Page 2

Q
D
E
E
A
F
G
X
D
S
Q
D
C
R
C
N
B
A
E
E
N
T
W
H
U
B
P
W
J
L
Y
M
J
SAD OUTLET
SAD OUTLET
SAS
OUTLET
TOP VIEW
W
E
I
V
E
D
I
S
W
E
I
V
T
N
O
R
F
* All measurements in inches.
D
45
45
48
1/4
48
1/4
H
100W
10012W
150W
15012W
WET
MODULE
NUMBER
SAS/SAD 100B
SAS/SAD 10012B
SAS/SAD 150B
SAS/SAD 15012B
BLOWER
MODEL
NUMBER
CABINET
W
44
44
54
54
63
3/8
67
3/8
66
5/8
70
5/8
C
(SAS)
13
19/32
13
19/32
16
13/16
16
13/16
A
DUCT
OPENING
B
21
3/4
21
3/4
26
7/8
26
7/8
21
3/4
21
3/4
26
7/8
26
7/8
U
(SAD)
21
11/32
21
11/32
19
5/32
19
5/32
E
P
(SAD)
11
5/8
11
5/8
10
11/16
10
11/16
1
29/32
1
29/32
2
7/32
2
7/32
DUCT
LOCATION
F
DRAIN
LOCATION
G
22
1/2
22
1/2
24
1/8
24
1/8
12
1/2
16
1/2
12
1/2
16
1/2
X
MEDIA
DIMENSION
Y
44
3/4
44
3/4
48
48
36
5/8
36
5/8
46
3/8
46
3/8
WET
MODULE
J
18
1/2
22
1/2
18
1/2
22
1/2
L
WATER
SERVICE
M
5
7/8
5
7/8
5
7/8
5
7/8
14
5/8
18
5/8
14
5/8
18
5/8
S
ELECTRIC
SERVICE
T
21
1/2
21
1/2
23
1/8
23
1/8
5
5/32
5
5/32
5
5/32
5
5/32
N
4
3/4
4
3/4
4
3/4
4
3/4
Q
SKID
LOCATIONS
R
4
3/4
4
3/4
4
3/4
4
3/4
42
42
52
52
DIMENSIONAL DATA*
PERFORMANCE
Certified Air Delivery At Various Increments Of Static Pressure (Inches Static Pressure Water Gauge)
INDEX TABLE
INDEX TABLE
CFM
SAS/SAD 100
PAGE 2
SAS/SAD 10012
PAGE 4
SAS/SAD 150
PAGE 6
SAS/SAD 15012
PAGE 8
AS/AD 100
PAGE 1
AS/AD 10012
PAGE 3
AS/AD 150
PAGE 5
AS/AD 15012
PAGE 7
AS/AD/AU
20012
PAGE 9
MODEL
& PAGE NO.
0"
0.1"
0.2"
0.3"
0.4"
0.5"
0.6"
Performance shown is for installation type B - free inlet, ducted outlet. Power rating (BHP) does not include
drive losses. Performance ratings do not include the effects of appurtenances in the airstream.
CFM
5377
5918
6774
5371
5911
6767
7072
7783
8910
N/A
N/A
6997
7702
8817
N/A
N/A
7745
8524
9758
11569
7431
8178
9362
11099
11405
13057
15480
17719
11375
13020
15438
17672
16267
19286
22077
24301
CFM
5121
5684
6574
5064
5627
6513
6622
7372
8548
9476
N/A
6539
7286
8455
9375
N/A
7530
8333
9596
11463
7255
8024
9235
11001
10892
12600
15082
17364
10905
12604
15084
17360
15716
18820
21670
23929
CFM
4863
5451
6366
4794
5375
6286
6203
6987
8205
9159
N/A
6087
6876
8091
9044
N/A
7275
8109
9407
11285
7052
7842
9075
10868
10463
12204
14735
17050
10482
12225
14749
17060
15200
18371
21270
23562
CFM
4605
5215
6164
4536
5142
6076
5769
6602
7870
8855
N/A
5603
6450
7734
8719
N/A
7004
7868
9204
11121
6835
7649
8914
10736
10064
11844
14410
16756
10079
11865
14434
16777
14696
17943
20888
23204
CFM
4336
4980
5956
4269
4907
5872
5298
6199
7533
8555
N/A
5051
5994
7359
8389
N/A
6729
7618
8990
10950
6611
7450
8744
10598
9671
11497
14106
16479
9678
11514
14133
16505
14190
17518
20514
22866
CFM
4058
4734
5751
3985
4663
5666
4777
5764
7182
8244
N/A
4415
5477
6961
8043
N/A
6460
7368
8773
10773
6376
7244
8572
10457
9276
11153
13810
16214
9265
11165
13838
16242
13665
17092
20142
22528
3754
4479
5537
3667
4399
5456
4201
5285
6812
7924
N/A
3717
4893
6525
7683
9377
6193
7123
8556
10592
6131
7030
8393
10313
8874
10815
13520
15947
8830
10807
13540
15983
13110
16661
19769
22190
0.8"
CFM
3097
3924
5095
2952
3809
5008
3041
4231
5993
7236
9032
2497
3637
5527
6869
8751
5646
6638
8124
10224
5610
6580
8024
10016
8006
10113
12948
15440
7867
10058
12899
15463
11886
15752
19015
21510
0.9"
CFM
--
3619
4859
2591
3480
4755
2522
3699
5537
6866
8741
2013
3085
4976
6416
8407
5357
6389
7913
10039
5327
6343
7827
9862
7530
9741
12659
15188
7325
9651
12640
15207
11194
15272
18629
21171
1.0"
CFM
--
3307
4613
2261
3145
4497
2040
3199
5067
6470
8436
1571
2609
4425
5932
8046
5045
6137
7698
9856
5031
6095
7631
9709
7017
9361
12361
14937
6753
9220
12328
14947
10450
14760
18229
20823
0.7"
CFM
3429
4209
5320
3318
4115
5238
3607
4764
6416
7592
9315
3058
4260
6050
7293
9070
5923
6878
8340
10407
5877
6809
8209
10165
8456
10467
13234
15694
8366
10440
13246
15724
12521
16211
19395
21852
HOW TO USE
THIS INDEX
Using the cooling
requirement variables of
Cooling Feet per Minute
and External Static
Pressure (shown as inches
of water), locate the
specific MasterCool model
required and its
corresponding page
number. Turn to the
indicated page for specific
Performance Data and
Sizing Tables. Follow the
Sizing Instructions on the
front inside cover to
determine the MasterCool
product for any cooling
installation.
ABLE