beautypg.com

Essick Air AS20012 User Manual

Page 10

background image

Q

D

E

E

A

F

G

X

D

S

Q

D

C

R

C

N

B

A

E

E

N

T

W

H

U

B

P

W

J

L

Y

M

J

SAD OUTLET

SAD OUTLET

SAS

OUTLET

TOP VIEW

W

E

I

V

E

D

I

S

W

E

I

V

T

N

O

R

F

* All measurements in inches.

D

45
45

48

1/4

48

1/4

H

100W

10012W

150W

15012W

WET

MODULE

NUMBER

SAS/SAD 100B
SAS/SAD 10012B
SAS/SAD 150B
SAS/SAD 15012B

BLOWER

MODEL

NUMBER

CABINET

W

44
44
54
54

63

3/8

67

3/8

66

5/8

70

5/8

C

(SAS)

13

19/32

13

19/32

16

13/16

16

13/16

A

DUCT

OPENING

B

21

3/4

21

3/4

26

7/8

26

7/8

21

3/4

21

3/4

26

7/8

26

7/8

U

(SAD)

21

11/32

21

11/32

19

5/32

19

5/32

E

P

(SAD)

11

5/8

11

5/8

10

11/16

10

11/16

1

29/32

1

29/32

2

7/32

2

7/32

DUCT

LOCATION

F

DRAIN

LOCATION

G

22

1/2

22

1/2

24

1/8

24

1/8

12

1/2

16

1/2

12

1/2

16

1/2

X

MEDIA

DIMENSION

Y

44

3/4

44

3/4

48
48

36

5/8

36

5/8

46

3/8

46

3/8

WET

MODULE

J

18

1/2

22

1/2

18

1/2

22

1/2

L

WATER

SERVICE

M

5

7/8

5

7/8

5

7/8

5

7/8

14

5/8

18

5/8

14

5/8

18

5/8

S

ELECTRIC

SERVICE

T

21

1/2

21

1/2

23

1/8

23

1/8

5

5/32

5

5/32

5

5/32

5

5/32

N

4

3/4

4

3/4

4

3/4

4

3/4

Q

SKID

LOCATIONS

R

4

3/4

4

3/4

4

3/4

4

3/4

42
42
52
52

DIMENSIONAL DATA*

SIZING TABLES

SHEAVE SELECTION

MOTOR SPECIFICATIONS

SPECIFICATIONS

PERFORMANCE

Certified Air Delivery At .1" Increments Of External Static Pressure

(Inches Static Pressure Water Gauge)

2

7

9

10

12

11

6

5

4

3

1

OUTDOOR WET-BULB

LAT

GPH

LAT

GPH

LAT

GPH

LAT

GPH

85

95

105

115

OUTDOOR

DRY BULB

TEMP.

OUTDOOR WET-BULB

OUTDOOR WET-BULB

Performance shown is for installation type B - Free inlet, Ducted outlet. Power rating (BHP) does not include drive losses. Models SAS/SAD 150 include the affects of an 8 inch thick evaporative media on the inlet.

, & Blower Speed are determined from the SPECIFICATION table above, use this information to select the proper pulley-belt kit from the SHEAVE SELECTION table below.

RPM

CFM RPM

RPM

CFM

CFM

SAS

MODEL

BELT

SAD

MODEL

BELT

OPER.

WGT.

CFM

MAX

B.H.P.

0"

0.1"

0.2"

0.3"

0.4"

0.5"

0.6"

RPM

CFM

RPM

CFM RPM CFM RPM

RPM

0.8"

CFM RPM

0.9"

CFM

RPM

1.0"

CFM RPM

0.7"

CFM

13.8/7.6-6.9

6.9

3.5-3.2/1.6

16/8

8

4.6-4.2/2.1

20/11-10

6.6-6/3

5/8
5/8
5/8
5/8
5/8
7/8
5/8
7/8

1
1
3
1
1
3
1
3

115/208-230

230

208-230/460

115/230

230

208-230/460
115/208-230
208-230/460

H.P.

VOLTS

BLOWER MOTORS

SPEED

1
2
1
1
2
1
1
1

24
29
20
28
29
34
41
40

110455
110456
110461
110457
110458

110462-9

110459-1

110463-9

3/4
3/4
3/4

1
1
1

1

1/2

1

1/2

PHASE

MOTOR

AMPS*

SHAFT

DIA.

MOTOR

WGT(LB)

MOTOR

PART NO.

24/13.2-12
7.5-6.8/3.4

10.6-9.6/4.8

7/8
7/8

1

1/8

1
3
3

115/208-230
208-230/460
208-230/460

H.P.

VOLTS

BLOWER MOTORS

SPEED

1
1
1

49
44
83

110460-1

110464-9
110465-9

2
2
3

PHASE

MOTOR

AMPS*

SHAFT

DIA.

MOTOR

WGT(LB)

MOTOR

PART NO.

*Amperage shown is from National Electrical Code. Use amperage shown on motor nameplate to determine motor protector.

WATTS

73
77

GPM (5 FT. HEAD)

4.6
4.6

PUMP PART NO.

110467
110468

VOLTS

115
230

AMPS

1.0

0.58

8

287
381
287
381
437
437

296
390
296
390
446
446

278
373
278
373
429
429

269
364
269
364
420
420

8350K
8450K

8350

8450K

8550
8550

B96
B96
B96
B96
B96

B100

SAS

MODEL

BELT

B90
B90
B90
B90
B90
B92

SAD

MODEL

BELT

5/8*
5/8*
7/8*
7/8*

7/8

1 1/8

MAUREY

SHEAVE

MOTOR

H.P.

BLOWER RPM/MOTOR SHEAVE 1/2 TURN DOWN

3/4

, 1

3/4

,1,

1

1, 1

1/2

, 2

1

1/2

, 2

3

253
347
253
347
403
403

261
356
261
356
412
412

304
398
304
398
454
454

313
407
313
407
463
463

321
415
321
415
471
471

330
424
330
424
480
480

338
432
338
432
488
488

347
441
347
441
497
497

3DI-130
3DI-135
3DI-140
3DI-145
3DI-155
3DI-161

SHEAVE

BORE

CHAMPION-SAD

PULLEY-BELT

KIT NO.

3DI-165
3DI-170
3DI-175
3DI-180
3DI-185
3DI-190

CHAMPION-SAS

PULLEY-BELT

KIT NO.

*When selecting 1 H.P. motor, be sure to select Pulley-Belt Kit with same pulley bore as shaft size of motor selected.

* Static Pressure (inches of water). GPH = Water consumption at design conditions but does not include bleed-off amount. Amount of bleed-off will vary with different water sources, but

an amount equal to 10% of water consumption at any design condition is considered sufficient for average water. LAT = Cooler Discharge Temperature.

Pumps - 1 Required.

6203
6987
8205
9159

N/A

298
324
365
399

N/A

287
314
356
390

N/A

6622
7372
8548
9476

N/A

B90
B90
B90
B90
B92

B96
B96
B96
B96

B100

584
593
608
612
624

3/4

1

1 1/2

2
3

7072
7783
8910

N/A
N/A

275
302
346

N/A
N/A

5769
6602
7870
8855

N/A

308
333
374
406

N/A

5298
6199
7533
8555

N/A

321
343
382
414

N/A

4777
5764
7182
8244

N/A

336
355
391
421

N/A

4201
5285
6812
7924

N/A

355
369
401
430

N/A

3041
4231
5993
7236
9032

402
406
424
448
493

2522
3699
5537
6866
8741

424
427
439
459
500

2040
3199
5067
6470
8436

443
448
456
471
509

3607
4764
6416
7592
9315

378
386
412
438
486

75

77

7

79
14
81
21
83
28

65

69
14
71
21
73
28
75
35

55

61
21
63
28




75

77

5

78

9

80
14
82
18

65

68

9

70
14
72
18
73
23

55

60
14
62
18




75

76

2

78

5

79

7

81

9

65

68

5

69

7

71

9

72
11

55

59

7

61

9



7072 / 0

4777 / .5

2040 /1.0

3/4 H.P. MOTOR / CFM-SP*

75

77

8

79
15
82
23
84
30

65

69
15
72
23
74
30
76
38

55

62
23
64
30




75

77

6

79
11
81
17
82
22

65

69
11
71
17
72
22
74
28

55

61
17
62
22




75

76

3

78

7

79
10
81
14

65

68

7

69
10
71
14
72
17

55

59
10
61
14




7783 / 0

5764 / .5

3199 /1.0

1 H.P. MOTOR / CFM-SP*

75

78

8

80
17
82
25
84
34

65

70
17
72
25
74
34
77
42

55

62
25
64
34




75

77

7

79
14
81
20
83
27

65

69
14
71
20
73
27
75
34

55

61
20
63
27




75

77

5

79

9

80
14
82
19

65

68

9

70
14
72
19
73
23

55

60
14
62
19




8910 / 0

7182 / .5

5067 / 1.0

1-1/2 H.P. MOTOR / CFM-SP*

75

77

9

80
17
82
26
84
34

OUTDOOR WET-BULB

65

70
17
72
26
74
34
77
43

55

62
26
64
34




75

77

8

80
15
82
23
84
31

65

70
15
72
23
74
31
76
39

55

62
23
64
31




75

77

6

79
12
81
18
83
24

65

69
12
71
18
73
24
75
30

55

61
18
63
24




9476 /.1

8244 / .5

6470 / 1.0

2 H.P. MOTOR / CFM-SP*

75








OUTDOOR WET-BULB

65








55








75

77

9

80
17
82
26
84
34

65

70
17
72
26
74
34
77
43

55

62
26
64
34




75

77

8

80
15
82
23
84
31

65

70
15
72
23
74
31
76
39

55

62
23
64
31




9315 / .7

8436 / 1.0

3 H.P. MOTOR / CFM-SP*

When the Cooler Model No, Motor H.P.

1

1/2

This manual is related to the following products: