5.2. DO-160E Qualifications
Table 11 DO 160E test criteria to which we test the RosenView VX
Description
DO-160E Section
DO-160E Category
Temperature and Altitude
4.0
A1
Temperature Variation
5.0
C
Humidity
6.0
A
Operational Shocks & Crash Safety
7.0
B
Vibration
8.0
S, Curve B
Explosive Atmosphere
9.0
N/A
Waterproofness
10.0
N/A
Fluids Susceptibility
11.0
N/A
Sand and Dust
12.0
N/A
Fungus Resistance
13.0
N/A
Salt Fog
14.0
N/A
Magnetic Effect
15.0
A
Power Input
16.0
Z,B
Voltage Spike
17.0
B
Audio Frequency Conducted
Susceptibility
– Power Inputs
18.0
Z
Induced Signal Susceptibility
19.0
AC
Radio Frequency Susceptibility (Radiated
and Conducted)
20.0
TT
Emission of Radio Frequency Energy
21.0
B
Lightning-induced Transient Susceptibility
22.0
N/A
Lightning Direct Effects
23.0
N/A
Icing
24.0
N/A
Electrostatic Discharge (ESD)
25.0
A
Fire, Flammability
26.0
C