Chapter 6 digital lines, Solenoid 1 on/off – Remote Processing RPC-2350 User Manual
Page 40
CHAPTER 6
DIGITAL LINES
6-7
J3
Pin #
82C55
Port/ Bit
Other use for line
Opto
Channel
What line is used for
Associated CAMBASIC variable,
function, or task number
4
B/2
Exam ple
Exam ple
Solenoid 1 on/off
SOL1 = status, BIT &41,2,SOL1
19
A / 0
LCD port J6
8
21
A / 1
LCD port J6
9
23
A / 2
LCD port J6
10
25
A / 3
LCD port J6
11
24
A / 4
LCD port J6
12
22
A / 5
LCD port J6
13
20
A / 6
LCD port J6
14
18
A / 7
LCD port J6
15
10
B/0
High curr./ Keypad
16
8
B/1
High curr./ keypad
17
4
B/2
High current
18
6
B/3
High current
19
1
B/4
High current
20
3
B/5
High current
21
5
B/6
High current
22
7
B/7
High current
23
13
C / 0
Shared w/J5 keypad
0
16
C / 1
Shared w/J5 keypad
1
15
C / 2
Shared w/J5 keypad
2
17
C / 3
Shared w/J5 keypad
3
14
C / 4
Shared w/J5 keypad
4
11
C / 5
Shared w/J5 keypad
5
12
C / 6
Shared w/J5 keypad
6
9
C / 7
Shared w/J5 keypad
7
26
Ground
Ground
2
+ 5V