TESTING THE DETECTOR

RISCO recommends performing a self test after installation and before final cover
mounting. The test can be performed manually (locally or remotely) or automatically
every 24 hours

Remote self-test (Manual Test)

This test requires that a command be given in order to be performed.
To activate the remote self-test:

Ensure that the Dipswitch SW8 is set to OFF.

Short the TEST terminal block to GND.

All LEDs will turn on to indicate test commencement and sequentially turn off
after each successful parameter test.

The detector unit self test examines the following parameters:

LED

Trouble

1

External power supply failure

2

Internal voltage faulty

4

Piezo sensor failure

5

Temperature sensor failure

3, 6-9

Not Applicable


All LEDs will turn off at the end of a successful test, except the POWER LED
(LED9) and the alarm relay opens for three seconds. If a malfunction occurs, one of
the LEDs remains lit.

Local self-test (Automatic Test)

Ensure that the Dipswitch SW8 is set to ON.
The RK66S detector runs a local/automatic SELF-TEST every 24 hours from the
time of initial power on. Test procedure and result presentation is as per the
Remote self-test above.