beautypg.com

Jumper selection, Seismic detector, 11 en – RISCO Group SEISMIC Detector RK66S User Manual

Page 11: Jumper function, Figure 4: schematic of eol resistors

background image

Seismic Detector

11

EN

JUMPER SELECTION

Jumper

Function

S.A (Stand Alone) /BUS

J12

Used to enable tamper indication during Stand Alone
or BUS mode.

Stand Alone mode (Default).

BUS connection mode.
(See RISCO system
programming manuals).

J13: Alarm EOL

J15: Tamper EOL

Jumpers J13 and J15 allow for the selection of Alarm
and Tamper resistance (1K, 2.2K, 4.7K, 5.6K and
6.8K) according to the control panel. Follow the
terminal block connection diagram in Figure 4 when
connecting the detector to a Double End Of Line
(DEOL) zone.

Figure 4: Schematic of EOL Resistors

Panel DEOL

TAMPER

ALARM

C NC

TAMPER

NO

RESISTOR

(Default)

1K

2.2K

4.7K

5.6K

6.8K

TAMPER EOL JUMPERS (J15)

NO

RESISTOR

(Default)

1K

2.2K

4.7K

5.6K

6.8K

ALARM EOL JUMPERS (J13)