Digital Inputs
CONFIGURATION
Two contacts, two operating modes
CONTACTS
Normally open switches (external excitation not required)
or open collector transistor
OPEN CIRCUIT
Approximately 5 VDC
VOLTAGE
LOGIC LEVELS
LO = 0 to 0.8 VDC, HI = 4.7 to 28 VDC
OPERATION
Mode 1: Program hold and step
Mode 2: Program run or reset
Digital Outputs
CONFIGURATION
2 or 4 open collector transistor
OPERATION MODES
Alarms, inner signal PV or SP zones, program segment time
signals, SP status (ramp up/down or soak), program run or
end alerts
TRANSISTOR RATING 24 VDC @ 50 mA
Serial Communications
PROTOCOLS
Modbus (ASCII, RTU), PC software,
SYNC (master SP control)
UNIT ADDRESS
1 to 99 (Max 31 units connected)
BAUD RATE
600, 1200, 2400, 4800, 9600, 19200 bps, user selectable
RESPONSE TIME
0 to 100 ms delay response time
10 ms increments user selectable
DATA
7 or 8 bit user selectable
PARITY
None, even, or odd
Approvals
UL RECOGNIZED
USA and Canada
Process Control Equipment
UL FILE NUMBER
E244207
CE COMPLIANT