background image

PELLET STOVES

Chapter 4

INSTALLATION AND USE MANUAL

page

43

Operation

Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited

4.15. SYNCHRONIZATION OF REMOTE CONTROL

Upon first start-up of the product, it may be necessary to get the stove

to recognize the new remote control. To carry-out this operation, follow

the simple instructions that follow:

• connect the stove to the socket and switch the power supply

button on

• ensure that the selector D of the emergency panel is in the

position REMOTE

• when the first text appears onto the display of the emergency

panel, press the embedded button G with the aid of a pointy

object (toothpick..)

• three flashing lines “---“ will appear on the display. Press the

on/off button of the remote control for confirmation.

The three flashing lines will disappear from the display and the stove

will recognise the new communication address of the remote control.

Recognition will also be confirmed by 4 acoustic sounds.

4.16. SAFETY DEVICES

The stove is fitted with the following safety devices:

PRESSURE SWITCH

Monitors depression in the smoke duct. It is designed to shut

down the pellet feed screw in the event of an obstructed flue or

significant back-pressure (from the wind).

SMOKE TEMPERATURE SENSOR.

Monitors the temperature of the smoke, and gives permission for

start-up or shuts the stove down when the smoke temperature

falls below the preset value.

PELLET HOPPER TEMPERATURE SENSOR.

If the temperature exceeds the preset safety level, it immediately

shuts down the running of the stove, and has to be reset

manually, after the stove has cooled, before the it will restart.

ELECTRICAL SAFETY

The stove is protected against violent surges of current by the

main fuse, which is located on the control panel at the rear of the

stove. Other fuses to protect the electronic boards are to be found

on the boards themselves.

FAILURE OF THE SMOKE EXTRACTION FAN

If the fan stops, the electronic board shuts off the supply of pellets

in good time, and an alarm is displayed.

BREAKDOWN OF THE REDUCTION MOTOR

If the reduction motor stops, the stove continues to function until

it has cooled down to the minimum level.

- OFF
- REMOTE

- ON

- MIN
- MED

- MAX