4.6.2. Setting the temperature unit of measure

The temperature unit of measure can be set to either Fahrenheit or

Celsius.
Only with the stove off, press button 4 for at least 5 seconds to

select the unit of temperature measurement, either Celsius (°C) or

Fahrenheit (°F).

The default setting of the remote control is degrees Celsius

(°C)

4.7. FIRST LIGHTING

4.7.1. Turning on/off from the remote control

The stove -- and as a result the display of the remote control -- is

turned on and off by pressing key 3 on the remote control for 2

seconds.
After a start-up phase that lasts about 15 minutes, the stove

will come up to full operating power.
After the stove is shut down by pressing button 3, the cooling-off

procedure begins. This includes interruption fuel loading, cleaning of

the grate continuation of ventilation until the stove is sufficiently cold.

This phase may last from 20 to 40 minutes depending on how long the

stove was lit and where it is located.

4.7.2. Note on first ignition

The first attempt at ignition may not be successful,

since the feeder screw is empty and it is not always

able to fill the grate with required amount of pellets

in time to ensure normal ignition

CANCEL THE ALARM CONDITION FROM THE

EMERGENCY PANEL (see paragraph 4.16), REMOVE

PELLETS IN THE GRATE AND REPEAT LIGHTING

After repeated attempts at lighting, if there is no flame even though

pellets are flowing normally, check that the grate is correctly

positioned. It must be placed where it adheres perfectly to its

housing and free of any ash incrustations. If after this check no

abnormalities are found, it means that there may be a problem with the

stove components or that installation may not have been carried out

correctly.

REMOVE THE PELLETS FROM THE BURNER AND

CONTACT AN AUTHORISED MCZ TECHNICIAN.