Serial communication, cont’d – Extron electronic Digital Video Scaler Series DVS 304 AD User Manual
Page 54

Serial Communication, cont’d
DVS 304 • Serial Communication
3-14
Command
ASCII Command
(host to scaler)
Response
(scaler to host)
Additional description
General Information
N
These commands are not case sensitive. Both (I) and (i) can be used interchangeably
I/i
Vid
X7!
• Aud
X7!
• Typ
X7#
• Std
X8!
• Pre
X8! X8! X8!
• Sdi
X7!
]
Query Firmware Version
N
These commands are not case sensitive. Both (Q) and (q) can be used interchangeably
Q/q
x.xx]
View the Firmware version.
Query Part Number
N
These commands are not case sensitive. Both (N) and (n) can be used interchangeably
N/n
60-736-01/-02
/-03/-04]
View the part number.
View Internal Temp.
20S
X8@
]
Internal temp. deg Celsius.
Front Panel Security Lockout (Executive Mode)
N
These commands are not case sensitive. Both (X) and (x) can be used interchangeably
Enable
1X/x
Exe1]
Limited front panel adjustments
only.
Disable
0x
Exe0]
Adjustments/selections can be
made from front panel.
View status
X
X8)
]
Show mode status.
(0= disabled, 1= enabled)
SDI Field Flip
Standard
73*0#
Flp 0]
Flip Fields
73*1#
Flp 1]
View
73#
Flp
X8)
]
(0= Standard, 1= Flipped)
Enhanced Mode
Set mode
52*
X%
#
Enh
X%
]
View mode
52#
Enh
X%
]
Refresh Lock
Enable
77*1#
RFl 1]
Disable
77*0#
RFl 0]
View status
77#
X8)
]
(0= Disabled, 1= Enabled)
Auto Memory
Enable
1M/m
Aut1]
Disable
0M/m
Aut0]
View status
M/m
X8)
]
(0= Disabled, 1= Enabled)
N
X%
= On/Off
0 = off/disable, 1 = on/enable
X7!
= Input selection
1 to 4
X7#
= Input video format
1 to 9 (see page 3-6)
X8)
= 0 or 1
X8!
= Input Standard:
0 = None, 1 = NTSC 3.58, 2 = PAL, 3 = NTSC 4.43, 4 = SECAM
X8@
= Internal temperature
(in degree Celsius)