Extron electronic Digital Video Scaler Series DVS 304 AD User Manual
Page 53

3-13
DVS 304 • Serial Communication
Command
ASCII Command
(host to scaler)
Response
(scaler to host)
Additional description
Auto Switch Mode
On
10*1#
Asw 1]
Set auto switch mode on.
Off
10*0#
Asw 0]
Set auto switch mode off.
View setting
10#
X8)
]
View the auto switch mode status.
(0= off, 1= on).
Blue Screen
On
8*1#
Blu 1]
Set blue screen on.
Off
8*0#
Blu 0]
Set blue screen off.
View setting
8#
X8)
]
View the current blue mode status
(0= off, 1= on)
Auto Image
Enable
55*1#
Img 1]
Activates auto image for all inputs.
Disable
55* 0#
Img 0]
Turn auto image off.
Execute
55* 2#
Img 2]
Apply auto image to the selected
input.
View
55#
X8)
]
View auto image setting.
(0= disabled, 1= enabled).
OSD (On Screen Display) duration
Select speed
20*
X9*
#
Dur
X9*
]
Sets the OSD duration
View speed
20#
X9*
]
View the On screen display time.
Text label (OSD) (Input 4 only)
Write Name
Esc
X8$
NI]
Nam 4]
Writes text
X8$
for input 4.
Read Name
Esc NI]
X8$
]
View text label for input 4
PIP size
PIP size
16*
X10%
#
Pmd
X10%
]
Select size of PIP window.
View
16#
X10%
]
View PIP window size.
PIP mode
PIP on
17*
X10)
#
Pip
X10)
]
Turn PIP mode on with PIP
window from input
X10)
.
PIP off
17*0#
Pip 0]
Turn PIP mode off.
View
17#
X10)
]
View selection status (on or off).
N
When PIP is active, all controls apply to the PIP window. The main window cannot be modified while PIP window is displayed.
Swap (when PIP mode is “On”)
%
Tke0]
Swap content between main and
PIP window.
PIP mode audio follow (Audio model only)
Set
19*
X10^
#
Ald
X10^
]
Select audio follow setting in PIP
mode.
View
19#
X10^
]
View audio follow status.
N
X8)
= 0 or 1
X8$
= Text label/Preset name:
Up to 16 characters
X9*
= OSD display setup:
0 to 5 seconds in 1 second steps
X10)
= PIP window input selection:
0 to 4
X10%
= PIP window size:
1 to 6 (see page 3-7)
X10^
= PIP audio setup:
1 to 6 (see page 3-7)