5. cleANING & mAINTeNANce

5.1.

Ensure that the unit is depressurised before carrying out any maintenance and drain all fluids from the main tank and from the fluid

supply tube.

5.2.

Clean up any spilled brake fluid and wipe down with a clean cloth.

5.3.

store in a clean, dry and childproof location.

4.4.

universal adaptors.

4.4.1. Universal adapters can be fitted to brake or clutch master cylinder fluid reservoirs using the universal adapter clamps, the two hook

bolts and chains. Wrap the chain around the brake or clutch master cylinder and locate through the two holes in the adaptor and the

two slots in the clamp, take out the slack in the chain using the nuts and then tighten the clamp to seal the adaptor to the master

cylinder (fig.6).