3. SPECIFICATION

Function

Range

Resolution

Accuracy

DC Voltage: (Auto Ranging)

Input Impedance: 7.8MΩ.

Maximum Input: 600V dc or 600V ac rms.

400.0mV

0.1mV

±0.5% reading ± 2 digits

4.000V

1mV

±1.2% reading ± 2 digits

40.00V

10mV

400.0V

100mV

600V

1V

±1.5% reading ± 2 digits

Function

Range

Resolution

Accuracy

AC Voltage: (Auto-ranging except 400mV)

Input Impedance: 7.8MΩ

Frequency Range:50 to 400Hz

Maximum Input: 600V dc or 600V ac rms

400.0mV

0.1mV

±1.5% reading ± 15 digits

4.000V

1mV

±1.2% reading ± 3 digits

40.00V

10mV

±1.5% reading ± 3 digits

400.0V

100mV

600V

1V

±2.0% reading ± 4 digits

Function

Range

Resolution

Accuracy

DC Current: (Auto-ranging for uA / mA)

Overload Protection: 0.5A / 250V and 10A / 250V

Fuse.

Maximum Input: 400mA dc or 400mA ac rms on uA /

mA ranges, 10A dc or ac rms on 10A range.

400.0µA

0.1µA

±1.0% reading ± 3 digits

4000µA

1µA

±1.5% reading ± 3 digits

40.00mA

10µA

400.0mA

100µA

10A

10mA

±2.5% reading ± 5 digits

Function

Range

Resolution

Accuracy

AC Current (Auto-ranging for uA / mA)

Overload Protection: 0.5A / 250V and 10A / 250V

Fuse.

Frequency Range: 50 to 400Hz

Maximum Input: 400mA dc or 400mA ac rms on uA /

mA ranges, 10A dc or ac rms on 10A range.

400.0µA

0.1µA

±1.5% reading ± 5 digits

4000µA

1µA

±1.8% reading ± 5 digits

40.00mA

10µA

400.0mA

100µA

10A

10mA

±3.0% reading ± 7 digits

Function

Range

Resolution

Accuracy

Resistance (Auto-ranging)

Input Protection: 250V dc or 250V ac rms.

400.0Ω

0.1Ω

±1.2% reading ± 4 digits

4.000KΩ

1Ω

±1.0% reading ± 2 digits

40.00KΩ

10Ω

±1.2% reading ± 2 digits

400.0KΩ

100Ω

4.000MΩ

1KΩ

40.00MΩ

10KΩ

±2.0% reading ± 3 digits

Function

Range

Resolution

Accuracy

Capacitance (Auto-ranging)

Input Protection: 250V dc or 250V ac rms.

4.000nF

1pF

±5.0% reading ± 5 digits

40.00nF

10pF

±5.0% reading ± 7 digits

400.0nF

0.1nF

±3.0% reading ± 5 digits

4.000µF

1nF

40.00µF

10nF

200.0µF

0.1µF

±5.0% reading ± 5 digits

TM103 Issue No: 2(I) - 18/06/14

© Jack Sealey limited

Original Language Version

This manual is related to the following products: