Range Resolution Accuracy

400 .0mV 0 .1mV

± 0 .5% of reading ± 2 digits

4 .000V 1mV

40 .00V

10mV

±1 .5% of reading ± 2 digits

400 .0V 100mV

1000V

1V

± 1 .8% of reading ± 2 digits

Range Resolution Accuracy

400 .0mV

0 .1mV

± 1 .5% of reading ± 30 dig

4 .000V

1mV

± 1 .0% of reading ± 3 digits

40 .00V

10mV

± 1 .5% of reading ± 3 digits

400 .0V 100mV

600V

1V

± 2 .0% of reading ± 2 digits

Range Resolution Accuracy

400 .0uA

0 .1uA

± 1 .0% of reading ± 3 digits

4000uA 1uA

40 .00mA

10uA

± 1 .5% of reading ± 3 digits

400 .0mA 100uA

4A

1mA

± 2 .5% of reading ± 5 digits

10A 10mA

Range Resolution Accuracy

400 .0Ω

0 .1Ω

± 1 .2% of reading ± 4 digits

4 .000kΩ

1Ω

± 1 .0% of reading ± 2 digits

40 .00kΩ

10Ω

± 1 .2% of reading ± 2 digits

400 .0kΩ

100Ω

4 .000MΩ

1kΩ

40 .00MΩ

10kΩ

± 2 .0% of reading ± 3 digits

Range Resolution Accuracy

400 .0uA

0 .1uA

± 1 .5% of reading ± 5 digits

4000uA 1uA

40 .00mA

10uA

± 1 .8% of reading ± 5 digits

400 .0mA 100uA

4A

1mA

± 3 .0% of reading ± 7 digits

10A 10mA

DC Voltage (Auto Ranging)

AC Voltage (Auto Ranging except 400mV)

Input Impedance: 10MΩ.

Maximum Input 600Vac rms or 600Vdc .

DC Current (Auto Ranging for uA and mA)

Input Impedance: 10MΩ.

Frequency Range: 50 to 400Hz .

Maximum Input: 600Vac rms or 600Vdc .

Overload Protection: 0 .5A/250V and 20A/250V

Fuse:

Maximum Input:400mAac rms or 400mAdc on uA/mA ranges

20A ac or dc rms on 10A range .

AC Current (Auto Ranging for uA and mA)

Overload Protection: 0 .5A/250V and 20A/250V

Fuse:

Frequency Range:50 to 400Hz

Maximum Input: 40mAac or 400mAdc rms on uA/mA ranges,

20Aac rms or dc on 20A range .

Resistance (Auto Ranging)

Range Resolution Accuracy

40 .00nF

10pF

± 5 .0% of reading ± 7 digits

400 .0nF 0 .1nF

4 .000uF

1nF

± 3 .0% of reading ± 5 digits

40 .00uF 10nF

100 .0uF

0 .1uF

± 5 .0% of reading ± 5 digits

Capacitance (Auto Ranging)

Input Protection: 250Vac rms or 250Vdc .

Input Protection: 250Vac rms or 250Vdc .

Range Resolution Accuracy

5Hz 0 .001Hz

50Hz

0 .01Hz

± 1 .5% of reading ± 5 digits

500Hz 0 .1Hz

5kHz 1Hz

50kHz

10Hz

± 1 .2% of reading ± 3 digits

500kHz 100Hz

10MHz

1kHz

± 1 .5% of reading ± 4 digits

Frequency (Auto Ranging)

Sensitivity: <0 .5V rms while <1MHz

Sensitivity: >3V rms while >1MHz

Overload Protection: 250Vac rms or dc .

Range Resolution Accuracy

0 .1%~99 .9%

0 .1%

± 1 .2% of reading ± 2 digits

Duty Cycle (Auto Ranging)

Pulse Width: >100us, <100ms

Frequency Width: 5Hz - 150kHz

Overload Protection: 250Vac rms or dc .

Range Resolution Accuracy

-20°C~+760°C 1°C

± 3 .0% of reading ± 3 digits

-4°F~+1400°F 1°F

(Meter only, probe accuracy

not included) .

Range

Resolution Accuracy

RPM 4 600~4000RPM

1RPM

600~1200RPM

10RPM

(X 10 RPM)

±2% of reading ± 4

RPM 2 300~4000RPM

1RPM

digits

/DIS 300~600RPM 10RPM

(x 10 RPM)

Temperature

Sensor: Type K Thermocouple

Range Resolution Accuracy

0 .3mA

1mV

± 10% of reading ±5 digits

typical

Diode test

Open Circuit Voltage: 1 .5Vdc typical

Overload Protection: 250Vac rms or dc .

Cylinder Range Resolution Accuracy

2CYL 0~180 .0°

3CYL 0~120 .0°

4CYL

0~90 .0° 0 .1°

± 2 .0% of reading ± 4 digits

5CYL 0~72 .0°

6CYL 0~60 .0°

8CYL 0~45 .0°

10CYL 0~36 .0°

Dwell Angle

Overload Protection: 250Vac rms or dc .

Effect Reading: >600RPM

Overload protection 250V ac rms or dc .

Overvoltage Category:

CAT111 600V .

Display:

4000 counts LCD display with function indication .

Polarity:

Automatic, (-) negative polarity indication .

Overrange:

“OL” mark indication .

Low Battery Indication:

The “BAT” is displayed when the battery voltage drops below the operating level .

Measurement Rate:

2 times per second nominal

Auto Power Off:

Meter automatically shuts down after approx 30 minutes of inactivity .

Operating environment:

0°C to 50°C (32° to 122°F) at < 70%relative humidity .

Storage Temperature:

-20° to 60°C (-4°F to 140°F) at <80% relative humidity .

For Inside Use:

Max Working Height:

2000mtr .

Power:

One 9V battery PP3 .

Dimensions:

146 (H) x 66 .2 (W) x41 .5 (D) mm

Approx Weight:

330g

Accuracy is given at 18°C to 28°C (65°F to 83°F) less than 70% relative humidity.

RPM (Tacho)

Audible Continuity

Audible threshold:

Less than 150Ω

Test Current:

<0 .3mA

Overload Protection: 250Vac rms or dc .

Original Language Version

3. SPECIFICATION

© Jack Sealey Limited

TA201 Issue No: 3(L) - 17/06/14