beautypg.com

Sealey MM18 User Manual

Page 2

background image

Handy compact unit, small enough to fit in your pocket, making it

ideal for basic circuit testing on the move. Features flip lid for

added screen protection and storage of leads. Conforms to

EN 61010-1 CAT II safety requirements. Supplied with test

leads.

Measures:

• AC and DC Voltage

• DC Current

• Resistance

• Audible Continuity

2. FEATURES

© Jack Sealey Limited

3. SPECIFICATION

Model No: ......................... MM18

Measures:

Voltage DC: ...................... 2V, 20V, 200V, 250V (±1.0%)

Voltage AC: ....................... 250V (±1.2%)

Current DC: ...................... 200mA (±1.2%)

Resistance: ....................... 2k Ω, 20k Ω, 200k Ω, 2000k Ω (±1.2%)

Continuity Audible: ............ Yes

Digits x Height: ................ 5 x 11mm

Batteries (Supplied): ......... 2 x 1.5V

Size (L x W x H): ............... 114 x 56 x 23mm

Weight: ............................. 101g

Conformity: ....................... EN 61010-1

Operation Environment:.... 0°C to 40°C

Relative Humidity:............. <75%

Storage Temperature: ....... -10°C to 50°C

Relative Humidity:............. <85%

1.

Display

3½ digit LCD, with a max. reading of 1999.

2.

Function

Used to select desired function.

3.

Range Switch

Used to select desired range.

4.

Test Probes

DC VOLTAGE

Range Resolution Accuracy

2V 0.001V

20V 0.01V

200V

0.1V

±(1.0% +5 digits)

250V 1V

Input Impedance:

1MΩ

Max. Allowable Input Voltage:

250V dc

AC VOLTAGE

Range Resolution Accuracy

200V 0.1V

250V

1V

±(1.2% +10 digits)

Input Impedance:

About 500kΩ

Frequency Range:

40Hz to 400Hz

Max. Allowable Input Voltage:

250V ac rms

Response:

Average, calibrated

in rms of sine wave

DC CURRENT

Range Resolution Accuracy

200mA 0.1mA

±(1.2% + 5 digits)

Overload Protection:

250mA/250V Fast fuse

RESISTANCE

Range Resolution Accuracy

2kΩ

0.001kΩ

20kΩ

0.01kΩ

200kΩ

0.1kΩ

±(1.2% +5 digits)

2000kΩ 1kΩ

Max Open Circuit Voltage:

About 0.4V

Overload Protection:

250V DC/AC rms

Original Language Version

MM18 Issue No:2(I)-09/09/14