3.6 activatinG components removeD from

tHe veHicLe’s eLectricaL system. (such as

fuel pumps, starter solenoids, magnetic clutches,

blower motors, cooling fans, lights etc.) (fig.6).

By using the probe tip together with the auxiliary

earth lead, components can be activated, thereby

testing their function.

3.6.1 set the selection switch to ‘tEst’ position

3.6.2 connect the auxiliary earth lead’s clip to the

negative terminal of the component to be tested.

contact the probe to the positive terminal of the

component. the test indicator should illuminate

GrEEn, indicating continuity through the component.

3.6.3 Whilst observing the test indicator, quickly press the

power switch to the single bar ‘PositiVE’ position

and release it. if the test indicator changes from

GrEEn to rED, you may proceed with further

activation.

3.6.4 if the test indicator went off instantly, the unit has

been overloaded. this could happen for the following

reasons:

a) Where the tip of the tester has made contact is a

direct earth or a negative voltage.

b) the component has a short circuit.

c) the component requires a high current (e.g. a starter

motor).

note: the unit is equipped with a built in circuit breaker

for overload protection. After the circuit breaker trips, it

will reset automatically.

3.3 measurinG Dc voLtaGe (fig.3).

3.3.1 set the selection switch to ‘VoLtAGE’ position.

3.3.2 connect the probe to the positive terminal of the circuit

and clip the auxiliary earth lead to the negative

terminal.

3.3.3 the voltage indicators will illuminate to indicate the

voltage of the circuit

fig.3

3.4 poLarity testinG (fig.4).

3.4.1 set the selection switch to ‘tEst’ position.

3.4.2 connecting the tip of the probe to a positive (+) circuit

will illiminate the test indicator rED.

3.4.3 connecting the tip of the probe to a negative (-) circuit

will illuminate the test indicator GrEEn.

3.4.4 connecting the tip of the probe to an open circuit will

fail to illuminate the test indicator.

3.5 continuity testinG (fig.5).

3.5.1 set the selection switch to ‘tEst’ position.

Do not

press the power switch.

3.5.2 using the probe tip together with the auxiliary earth

lead, continuity can be tested on wires and components

which are disconnected from the vehicle’s electrical

system.

3.5.3 When continuity is present the test indicator will

illuminate GrEEn.

fig.4

fig.5

fig.6

Original Language Version