background image

The TEMPERATURE WARNING INDICATOR flashes red when the

internal

temperature of the projector exceeds the normal temperature.

Possible causes for the temperature warning may be:

1. Ventilation slots of the projector are blocked. In such an event,

reposition

the projector so that ventilation slots are not obstructed.

2. Air filter is clogged with dust particles. Remove dust from the air

filter by

following instructions in the Air Filter Care and Cleaning section

above.

If the TEMPERATURE WARNING INDICATOR still continues to flash after

checking (1) and (2), call your authorized dealer or service station.

The removable air filter prevents dust from accumulating on the surface of

the projection lens and projection mirror. Should

the air filter become

clogged with dust particles, it will reduce the cooling fan’s

effectiveness and may result in internal heat

build up and reduce the life

of the projector.

To clean the air filter, follow the cleaning procedures below:

Turn the POWER ON/OFF button OFF.

2. Remove the

air filter cover.

3. Remove

the

air filter and sponge

from the filter cover.

4. Clean the air filter with a vacuum cleaner.

5. Replace the air filter and sponge. Make sure that air filter cover is

fully inserted.

Do not clean with water. Doing so may damage the air filter.

Do not operate the projector with air filter removed.

TO ENJOY PICTURE IMAGE, USE THE PROJECTOR IN THE CLEAN

ENVIRONMENT. USAGE IN THE CLEAN ENVIRONMENT IS

RECOMMENDED.

When used under the

dusty or smoky conditions, dust may accumulate on the

liquid crystal panel and lens inside

it, and may resultantly be projected on

the screen together with the picture.

When the above symptoms are

noticed contact the place where your authorized dealer or service station for

the cleaning.