Hydrosteel 6000 MANUAL

Ion Science Ltd

Page 24 of 39

Unrivalled Detection. www.ionscience.com

Data logging and computer interface


Main ISLPC Menu Functions

File

Print

Print highlighted (Numerical or Graphical) data file via your PC.

Print Preview

Allows you to view the currently chosen data file for next print.

Print Set-up

Allows the characteristics of the printer that is connected to your PC to be selected.

Recent File

Allows access to recently used files.

Exit

Exit the ISL Data Interface Software application.

Data

Download Data

Reads measurement data from the ISL instrument.

Save, Save As

Saves highlighted (Numerical and Graphical) data to PC file, in an encrypted format (*.phd). This is
highly recommended to avoid having to download the same data again later, or to avoid losing data
later on.
There are 2 levels of protection used to stop changes to records: the first level is data encryption
and the second level is the watermark inserted by the islpc program into the encrypted data.

Open

Allows access to stored measurement data files. Refer to Section 4. The islpc program searches for
the file validity before opening data, and VALID will then be inserted into the header data of an open
file.

Close

Closed highlighted (Numerical or Graphical) window. Caution: Before closing the programme, from
the Data sub-menu, ensure you either Save data downloaded from the analyser, or export the data,
for use in spreadsheets such as Microsoft Excel.

Export

Saves highlighted data as a comma separated variable file, *.csv file, for external analysis using
standard spreadsheets, e.g. Excel. Please note *.csv files cannot be read by islpc.exe. The *.csv
file contains a summary of all data files, followed by data presented in chronological order.


Instrument

Download Data

Downloads measurement data from the ISL
instrument. Provides the same facility as the Data
menu.

Erase All Data

Erases all data stored in the ISL instrument.

Caution:

Ensure that any relevant data has been
downloaded before using this option.

Clear Zone Headers

Clears the zone headers stored in the ISL instrument.
As a consequence, all stored data is also erased -
caution: ensure that any relevant data has been
downloaded before using this option.

Instrument Details

Reads details of the ISL instrument currently interrogated using the IR_Link. Serial Number, Log
Memory Used, Log Memory Free and the Instrument On-time are specified.