Yaskawa G7 Modbus Communication User Manual
Page 61

61
Table 4.9 “F” Parameters
Access Level
Name
Address
Description
Data
Range
Unit
Default
During
Run
V/f
V/f
w/PG
OLV
FV
OLV2
0
During Run 1
1 Zero
Speed
2 Fref/Fout
Agree1
3
Fref/Set Agree 1
4
Frequency Detection 1
5
Frequency Detection 2
6 Inverter
Ready
7 DC
Bus
Undervoltage
8 Baseblock
1
9 Option
Reference
A Remote
Operation
B
Torque Detection 1 N.O.
C
Frequency Reference Loss
D DB
Overheat
E Fault
F Not
Used
10 Minor
Fault
(Alarm)
11
Fault Reset Command Active
12 Timer
Output
13
Fref/Fout Agree 2
14
Fref/Set Agree 2
15
Frequency Detection 3
16
Frequency Detection 4
17
Torque Detection 1 N.C.
18
Torque Detection 2 N.O.
19
Torque Detection 2 N.C.
1A Reverse
Direction
1B Baseblock
2
1C Motor
2
Selected
1D Regenerating
1E Restart
Enabled
1F Motor
Overload
(OL1)
20 OH
Pre-alarm
37
During Run 2
F5-01 0399h
DO-02C/DO-08 Option Kit
Channel 1 Selection
38 drive
Enable
1 0h - - - - -
F5-02 039Ah
DO-02C/DO-08
Channel 2 Selection
See
F5-01
1 01h A A A A A
F5-03
039Bh
DO-08 Channel 3 Selection
See F5-01
1
02h
A
A
A
A
A
F5-04
039Ch
DO-08 Channel 4 Selection
See F5-01
1
04h
A
A
A
A
A
F5-05
039Dh
DO-08 Channel 5 Selection
See F5-01
1
06h
A
A
A
A
A
F5-06
039Eh
DO-08 Channel 6 Selection
See F5-01
1
37h
A
A
A
A
A
F5-07
039Fh
DO-08 Channel 7 Selection
See F5-01
1
0fh
A
A
A
A
A
F5-08
03A0h
DO-08 Channel 8 Selection
See F5-01
1
0fh
A
A
A
A
A
0
8 Channel Fixed
1 Binary
Output
F5-09 03A1h
DO-08
Selection
2
8 Channel Selectable
(F5-01 ~ F5-08)
1
0
A A A A A
0
Ramp to Stop
1
Coast to Stop
2 Fast-Stop
(C1-09)
F6-01 03A2h
Communication Bus Fault
Selection (BUS)
3 Alarm
Only
1
1
A A A A A
0 Always
Detected
F6-02 03A3h
EF0
Detection
1
Only During Run
1
0
A A A A A
0
Ramp to Stop
1
Coast to Stop
2 Fast-Stop
(C1-09)
F6-03
03A4h
EF0 Fault Selection
3 Alarm
Only
1
1
A A A A A