(2)
Receive Message Function
*The CH-NO 1~4 are for message transmission between PCLINKs, and 5 is for reception from the MEMOBUS
port.
Function Name
MSG-RCV
Function
The messages are received from the counterpart station on the line designated in the transmission device
type. Multiple protocol types are supported.
Hold the execution command (EXECUTE) until COMPLETE or ERROR go "ON".
Transmission Device: PC-LINK
Protocol: MEMOBUS, non-procedural
Function
Definition
I/O Definition
No.
Name
I/O
Designation
Content
Input Items
1
EXECUTE
B-VAL
Receive Message Command
2
ABORT
B-VAL
Message Reception Forced Stop Command
3
DEV-TYP
I-REG
Transmission Device Classification
PC-LINK=3
4 PRO-TYP I-REG
Transmission
Protocol
MEMOBUS=1, Non-procedural 1=2, Non-procedural 2=3
5 CIR-NO
I-REG
Circuit
Number
PC-LINK = 1~8
6
CH-NO
I-REG
Transmission Buffer Channel Number
PC-LINK = 1~5
7
PARAM
Address Input
Set Data Lead Address
(MW, DW)
Output Items
1
BUSY
B-VAL
During Message Reception
2
COMPLETE
B-VAL
Message Reception Completed
3 ERROR
B-VAL
Error
Generation
ÁÂÁÃÄÅÁ