6 Installation Procedure
EN 22
YASKAWA Europe YEU TOEP C710606 98A - V1000 Option EtherCAT - Installation Manual
6. Connect the ground wire between the drive ground terminal and the EtherCAT
®
Option
ground. When wiring the EtherCAT
®
Option, pass the ground wire through the inside of the
drive bottom cover, then pass the ground wire into the through-hole for the ground wire at
the front of the EtherCAT
®
Option.
Figure E.5
Ground Wire Connection
7. Connect the communication wire to the EtherCAT
®
Option modular connector.
8. Attach the EtherCAT
®
Option cover to the front of the EtherCAT
®
Option.
Figure E.6
Attach Cover
Drive ground
terminal
Through-hole
for ground wire
Ground wire
Pass the ground
wire through
the bottom cover
of the drive.
Tabs should line up