beautypg.com

Yaskawa Varispeed-686SS5 CIMR-SSA User Manual

Page 68

background image

7

TROUBLESHOOTING

69

Table 31

Fault Diagnosis and Corrective Actions (Cont’d)

Fault Display

Description

Details

Corrective Action

Rank*

Braking resistor unit overheat
(RH)

The braking resistor unit temperature has
exceeded the allowable value.
(Protects only inverter built-in type)

Reduce the regenerative load.

A

Transmission fault with trans-
mission option (bUS)

Transmission fault with transmission op-
tion (detectedwhen thefault contirnuedfor
2.5 seconds)

Check the transmission devices and the
transmission signals.

A

External fault from transmis-
sion option (EF0)

External fault was input from the transmis-
sion option.

External fault, defined by user specifica-
tion, was input from the transmission op-
tion. Find the external fault items from the
I/O list and correct it.

B

External fault at terminal 3
(EF3)

B

External fault at terminal 4
(EF4)

B

External fault at terminal 5
(EF5)

Fault occurred in the external control
circuit.

Check the condition of the input terminal.
If the fault is displayed when terminal is

B

External fault at terminal 6
(EF6)

circuit.
The inverter operates according to the set-
tings of constants H1-01 to H1-06.

If the fault is displayed when terminal is
not connected, replace the inverter.

B

External fault at terminal 7
(EF7)

B

External fault at terminal 8
(EF8)

B

Control circuit fault 1 (CPF00)
(Digital operator transmission
fault)

• Transmission between the inverter and

digital operator cannot be established 5
seconds after supplying power.

• MPU peripheral element check fault

(initial)

• Insert the digital operator connector

again

A

Control circuit fault 2 (CPF01)
(Digital operator transmission
fault)

• Transmission between the inverter and

digital operator is established once after
supplying power, but later transmission
fault continues for more than 2 seconds.

• MPU peripheral element check fault

(initial)

again.

• Check the control circuit wiring.
• Replace the control card.

A

Baseblock circuit fault (CPF02)

A

EEPROM fault (CPF03)

A

CPU internal A/D converter

fault (CPF04)

Inverter control unit fault.

Replace the control card.

A

CPU external A/D converter

fault (CPF05)

A

Option card connection fault

(CPF06)

The option card is not installed correctly. Install the option card again.

A

A/D converter fault in option

card (CPF20)

Option card (AI-14B/U) A/D converter

fault

• Check the option card contact part.
• Replace the option card.

A

Cross-diagnose fault between
transmission option and control
card (CPF23)

Diagnosis data has not been updated for
more than 0.2 seconds between the trans-
mission option and the control card.

• Check the transmission option contact

part.

• Replace the transmission option.

A

EEPROM writing fault (Err)

EEPROM internal data did not match

when initializing the constant.

Replace the control card.

A

kVA selection fault (OPE01)

kVA selection fault

Check and set the constant data.

D

Constant setting range fault

(OPE02)

Constant data is out of range.

Check the constant data settings.

D

Multi-function contact input

selection fault (OPE03)

The same values are set except for F and

FF.

Check the function selection.

D

(Cont’d)